<strong>INSERTO</strong> <strong>Crystal</strong> <strong>50</strong> – <strong>50</strong> VERTICALE – <strong>70</strong> – <strong>80</strong> – <strong>100</strong><br />

5.1. CHIMNEY CAP<br />

The draught of the flue depends also on the suitability of the chimney cap.<br />

Therefore, if it is handicraft constructed, the output section must be more than twice as big as the internal section of<br />

the flue.<br />

Should it be necessary to exceed the ridge of the roof, the chimney cap must assure the discharge also in case of<br />

windy weather (Picture 7).<br />

The chimney cap must meet the following requirements:<br />

• have internal section equivalent to that of the stack.<br />

• have a useful output section twice as big as the flue internal one.<br />

• be manufactured in such a way as to prevent the penetration of rain, snow, and any other foreign body in the flue.<br />

• be easily checkable, for any possible maintenance and cleaning operation.<br />

<strong>50</strong> cm<br />

(1) Industrial chimney cap<br />

with pre-fabricated<br />

elements – it allows an<br />

excellent discharge of the<br />

smokes.<br />

2 m 10 m<br />

1<br />

m<br />

H min.<br />

α<br />

(2) Handicraft chimney<br />

cap. The right output<br />

section must be at least<br />

twice as big as the internal<br />

section of the flue (ideal<br />

value: 2.5 times).<br />

(3) Chimney cap for<br />

steel flue with internal<br />

cone deflector of<br />

smokes.<br />

Picture 7<br />

(1) The chimney cap must not show hindrances within 10 m from<br />

walls, pitches and trees. Otherwise raise it of at least 1 m over the<br />

hindrance.<br />

The chimney cap must exceed the ridge of the roof of at least 1 m.<br />

Picture 8<br />

(1) In case of flues side by side, a chimney cap must be higher<br />

than the other one of at least <strong>50</strong> cm in order to avoid pressure<br />

transfers between the flues themselves.<br />

>A<br />

> _ A<br />

(1)Ridge axis<br />

(2)Roof<br />

Picture 9<br />

Picture 10<br />

6096<strong>80</strong>1 - Rev.09 – EN 21<br />