<strong>INSERTO</strong> <strong>Crystal</strong> <strong>50</strong> – <strong>50</strong> VERTICALE – <strong>70</strong> – <strong>80</strong> – <strong>100</strong><br />
5.1. CHIMNEY CAP<br />
The draught of the flue depends also on the suitability of the chimney cap.<br />
Therefore, if it is handicraft constructed, the output section must be more than twice as big as the internal section of<br />
the flue.<br />
Should it be necessary to exceed the ridge of the roof, the chimney cap must assure the discharge also in case of<br />
windy weather (Picture 7).<br />
The chimney cap must meet the following requirements:<br />
• have internal section equivalent to that of the stack.<br />
• have a useful output section twice as big as the flue internal one.<br />
• be manufactured in such a way as to prevent the penetration of rain, snow, and any other foreign body in the flue.<br />
• be easily checkable, for any possible maintenance and cleaning operation.<br />
<strong>50</strong> cm<br />
(1) Industrial chimney cap<br />
with pre-fabricated<br />
elements – it allows an<br />
excellent discharge of the<br />
smokes.<br />
2 m 10 m<br />
1<br />
m<br />
H min.<br />
α<br />
(2) Handicraft chimney<br />
cap. The right output<br />
section must be at least<br />
twice as big as the internal<br />
section of the flue (ideal<br />
value: 2.5 times).<br />
(3) Chimney cap for<br />
steel flue with internal<br />
cone deflector of<br />
smokes.<br />
Picture 7<br />
(1) The chimney cap must not show hindrances within 10 m from<br />
walls, pitches and trees. Otherwise raise it of at least 1 m over the<br />
hindrance.<br />
The chimney cap must exceed the ridge of the roof of at least 1 m.<br />
Picture 8<br />
(1) In case of flues side by side, a chimney cap must be higher<br />
than the other one of at least <strong>50</strong> cm in order to avoid pressure<br />
transfers between the flues themselves.<br />
>A<br />
> _ A<br />
(1)Ridge axis<br />
(2)Roof<br />
Picture 9<br />
Picture 10<br />
6096<strong>80</strong>1 - Rev.09 – EN 21<br />
0,5 m