<strong>INSERTO</strong> <strong>Crystal</strong> <strong>50</strong> – <strong>50</strong> VERTICALE – <strong>70</strong> – <strong>80</strong> – <strong>100</strong><br />
15. SUMMER TIME<br />
After having performed the cleaning of the hearth, of the stack and of the flue, by removing completely the ash and<br />
other possible residuals, close all hearth doors and related registers.<br />
It is suggested to perform the flue cleaning at least once a year; in the meantime, verify the actual state of the door<br />
seals, which do not assure the good operation of the appliance, if they are not completely integral (i.e. if they do not<br />
adhere anymore to the door)! Therefore, it is necessary to replace them.<br />
In case of humidity of the room where the appliance is located, place the absorbing salts within the hearth.<br />
Protect the internal cast iron parts with neutral Vaseline, if you wish to keep the aesthetic appearance unchanged in<br />
time.<br />
16. CALCULATION OF THE THERMAL POWER.<br />
There is not an absolute rule for calculating the correct necessary power. This power is given according to the space<br />
to be heated, but it depends also largely on the insulation. On an average, the calorific value necessary for a properly<br />
insulated room is 40 kCal/h per m 3 (for an external temperature of 0 °C).<br />
Given that 1 kW corresponds to 860 kCal/h, it is possible to adopt a value of <strong>50</strong> W/m 3 .<br />
Let’s suppose that one wishes to heat a room of 1<strong>50</strong> m 3 (10 x 6 x 2.5 m) in an insulated apartment, it is necessary to<br />
have 1<strong>50</strong> m 3 x <strong>50</strong> W/m 3 = 7<strong>50</strong>0 W or 7.5 kW.<br />
Therefore as main heating, a 10 kW appliance is sufficient.<br />
Approximate combustion value<br />
Fuel Unit kCal kW<br />
Quantity required for<br />
1 kg of dry wood<br />
Dry wood (15% humidity) kg 3600 4.2 1.00<br />
Wet wood (<strong>50</strong>% humidity) kg 18<strong>50</strong> 2.2 1.95<br />
Wood briquettes kg 4000 5.0 0.84<br />
Brown coal briquettes kg 4<strong>80</strong>0 5.6 0.75<br />
Normal anthracite kg 7<strong>70</strong>0 8.9 0.47<br />
Coke kg 67<strong>80</strong> 7.9 0.53<br />
Natural gas m 3 7<strong>80</strong>0 9.1 0.46<br />
Naphtha L 8<strong>50</strong>0 9.9 0.42<br />
Electricity kW/h 860 1.0 4.19<br />