15. SUMMER TIME<br />

After having performed the cleaning of the hearth, of the stack and of the flue, by removing completely the ash and<br />

other possible residuals, close all hearth doors and related registers.<br />

It is suggested to perform the flue cleaning at least once a year; in the meantime, verify the actual state of the door<br />

seals, which do not assure the good operation of the appliance, if they are not completely integral (i.e. if they do not<br />

adhere anymore to the door)! Therefore, it is necessary to replace them.<br />

In case of humidity of the room where the appliance is located, place the absorbing salts within the hearth.<br />

Protect the internal cast iron parts with neutral Vaseline, if you wish to keep the aesthetic appearance unchanged in<br />

time.<br />

16. CALCULATION OF THE THERMAL POWER.<br />

There is not an absolute rule for calculating the correct necessary power. This power is given according to the space<br />

to be heated, but it depends also largely on the insulation. On an average, the calorific value necessary for a properly<br />

insulated room is 40 kCal/h per m 3 (for an external temperature of 0 °C).<br />

Given that 1 kW corresponds to 860 kCal/h, it is possible to adopt a value of <strong>50</strong> W/m 3 .<br />

Let’s suppose that one wishes to heat a room of 1<strong>50</strong> m 3 (10 x 6 x 2.5 m) in an insulated apartment, it is necessary to<br />

have 1<strong>50</strong> m 3 x <strong>50</strong> W/m 3 = 7<strong>50</strong>0 W or 7.5 kW.<br />

Therefore as main heating, a 10 kW appliance is sufficient.<br />

Approximate combustion value<br />

Fuel Unit kCal kW<br />

Quantity required for<br />

1 kg of dry wood<br />

Dry wood (15% humidity) kg 3600 4.2 1.00<br />

Wet wood (<strong>50</strong>% humidity) kg 18<strong>50</strong> 2.2 1.95<br />

Wood briquettes kg 4000 5.0 0.84<br />

Brown coal briquettes kg 4<strong>80</strong>0 5.6 0.75<br />

Normal anthracite kg 7<strong>70</strong>0 8.9 0.47<br />

Coke kg 67<strong>80</strong> 7.9 0.53<br />

Natural gas m 3 7<strong>80</strong>0 9.1 0.46<br />

Naphtha L 8<strong>50</strong>0 9.9 0.42<br />

Electricity kW/h 860 1.0 4.19<br />