<strong>INSERTO</strong> <strong>Crystal</strong> <strong>50</strong> – <strong>50</strong> VERTICALE – <strong>70</strong> – <strong>80</strong> – <strong>100</strong><br />

9. CONNECTION AND MAINTENANCE OF VENTILATION<br />

The control unit and the plant must be installed and connected by authorized personnel according to the<br />

standards in force. (see chapter.1)<br />

ATTENTION: the feeding cable must not be in contact with hot parts.<br />

Our inserts are equipped with tangential fans suitable to improve the distribution of heat through the ventilation<br />

exclusively of the installation room. (see chapter.6)<br />

The lighting and the adjustment is carried out through the proper standard supplied control unit that has to be installed<br />

far from any direct heat source. The kit is equipped with a thermostat (TM) that lets the fans start when the appliance<br />

is properly heated, and stops them when it is partially cold.<br />

If the control is switched on pos. I halfway speed – pos. II maximum speed, the ventilators work when a pre-set<br />

temperature is achieved.<br />

The control unit is provided with a fuse inside in order to protect the engine and the control unit itself.<br />

(Delayed glass fuse 5x20 <strong>50</strong>0 mA (T)).<br />

The selection of the kind of insert to be connected is in the control unit and has to be done by moving the small bridge<br />

as shown hereafter (see the Picture 19) before the INSERT starts to operate. This operation must be done without<br />

electric energy!!<br />

CONNECTION TO THE TERMINAL<br />

L / Ph Power supply Phase Color: Brown<br />

N Power supply Neutral Color: Blue<br />

E Power supply<br />

E Motor cable<br />

Color: yellow/green<br />

Color: yellow/green<br />

M Thermostat cable Color: Blue<br />

M Motor cable Color: Brown<br />

Thermostat<br />

MANDATORY: cable<br />

out of seeing!<br />

Picture 17<br />

Picture 18<br />

L<br />

Ph<br />

N E E M M<br />

TECHNICAL FEATURES<br />

POWER SUPPLY 230 V~ ±10% <strong>50</strong>/60 Hz<br />

PROTECTION Internal fuse <strong>50</strong>0 but T RIT<br />

DIMENSIONS 104 x 75 x 32 mm<br />

CONTAINER Self-extinguishing ABS IP42 V0<br />

CONNECTION:<br />

Connect the feeding cable of the switchboard with an electronic bipolar switch respecting at least a 3 mm distance<br />

between the contacts (power supply 230V~ <strong>50</strong>Hz, it is necessary to provide for the correct connection to the<br />

grounding plant). See chapter 19<br />

For the connection of the OPTIONAL ventilation kit, please see chapter 20.<br />

WARNING: The COMMAND must be connected to the mains with a differential line cut-off switch according to<br />

the regulations in force. Correct operation of the command is assured only for the proper motor for<br />

which it has been manufactured. Improper use relieves the manufacturer from each responsibility.<br />

6096<strong>80</strong>1 - Rev.09 – EN 25<br />

Marrone<br />

Blu<br />

Giallo / Verde<br />

230 V~ <strong>50</strong>Hz<br />

Blu<br />

TM<br />

Marrone<br />

Blu<br />

M M<br />

Giallo / Verde<br />