9. CONNECTION AND MAINTENANCE OF VENTILATION<br />
The control unit and the plant must be installed and connected by authorized personnel according to the<br />
standards in force. (see chapter.1)<br />
ATTENTION: the feeding cable must not be in contact with hot parts.<br />
Our inserts are equipped with tangential fans suitable to improve the distribution of heat through the ventilation<br />
exclusively of the installation room. (see chapter.6)<br />
The lighting and the adjustment is carried out through the proper standard supplied control unit that has to be installed<br />
far from any direct heat source. The kit is equipped with a thermostat (TM) that lets the fans start when the appliance<br />
is properly heated, and stops them when it is partially cold.<br />
If the control is switched on pos. I halfway speed – pos. II maximum speed, the ventilators work when a pre-set<br />
temperature is achieved.<br />
The control unit is provided with a fuse inside in order to protect the engine and the control unit itself.<br />
(Delayed glass fuse 5x20 <strong>50</strong>0 mA (T)).<br />
The selection of the kind of insert to be connected is in the control unit and has to be done by moving the small bridge<br />
as shown hereafter (see the Picture 19) before the INSERT starts to operate. This operation must be done without<br />
electric energy!!<br />
CONNECTION TO THE TERMINAL<br />
L / Ph Power supply Phase Color: Brown<br />
N Power supply Neutral Color: Blue<br />
E Power supply<br />
E Motor cable<br />
Color: yellow/green<br />
Color: yellow/green<br />
M Thermostat cable Color: Blue<br />
M Motor cable Color: Brown<br />
Thermostat<br />
MANDATORY: cable<br />
out of seeing!<br />
Picture 17<br />
Picture 18<br />
L<br />
Ph<br />
N E E M M<br />
TECHNICAL FEATURES<br />
POWER SUPPLY 230 V~ ±10% <strong>50</strong>/60 Hz<br />
PROTECTION Internal fuse <strong>50</strong>0 but T RIT<br />
DIMENSIONS 104 x 75 x 32 mm<br />
CONTAINER Self-extinguishing ABS IP42 V0<br />
CONNECTION:<br />
Connect the feeding cable of the switchboard with an electronic bipolar switch respecting at least a 3 mm distance<br />
between the contacts (power supply 230V~ <strong>50</strong>Hz, it is necessary to provide for the correct connection to the<br />
grounding plant). See chapter 19<br />
For the connection of the OPTIONAL ventilation kit, please see chapter 20.<br />
WARNING: The COMMAND must be connected to the mains with a differential line cut-off switch according to<br />
the regulations in force. Correct operation of the command is assured only for the proper motor for<br />
which it has been manufactured. Improper use relieves the manufacturer from each responsibility.<br />
6096<strong>80</strong>1 - Rev.09 – EN 25<br />
Marrone<br />
Blu<br />
Giallo / Verde<br />
230 V~ <strong>50</strong>Hz<br />
Blu<br />
TM<br />
Marrone<br />
Blu<br />
M M<br />
Giallo / Verde<br />
20mm