Remote control<br />

The time-thermostat has a serial connection for connecting to the GSM GW 90 821 remote<br />

control unit. Using SMS command (e.g. from a cellular telephone) it is possible to:<br />

• set the type of operation (air conditioning/heating)<br />

• set the operating mode (manual/automatic/OFF)<br />

• set the operating set point (MAN mode only)<br />

• request the current status<br />

The device replies to each command SMS sent with a confirmatory SMS (with a predefined,<br />

non-configurable text); the status request message will generate a reply that includes the<br />

following information:<br />

• current type of operation (heating/air conditioning)<br />

• current operating mode (OFF/AUTO/MAN)<br />

• currently set set point temperature<br />

• measured ambient temperature<br />

• output status (ON/OFF)<br />

The symbol is displayed on the VDU whenever the operating type or mode are modified<br />

using the remote control unit.<br />

E<br />

N<br />

G<br />

L<br />

I<br />

S<br />

H<br />

Operating in the case of a blackout<br />

The device is fitted with a backup battery that guarantees updating of the time and the day<br />

of the week in the case of a blackout. There is an autonomy of 48 hours under the following<br />

conditions when the power supply is provided exclusively by the battery:<br />

• display time active<br />

• measure and temperature display not active (dashes are displayed)<br />

• backlighting not active<br />

• relay switching not enabled (the relay contact is open)<br />

• front keys not active (except the simultaneous pressing of all four keys). In the absence<br />

of the power supply the simultaneous pressing of all four front keys causes disconnection<br />

of the backup battery inside the device.<br />

This function is used to conserve the efficiency of the battery when the device is not used<br />

for a long period. The battery is automatically reconnected once the device is connected to<br />

the electricity mains network. The set programs are not lost either in the case of a blackout<br />

or in the case of battery disconnection.<br />