Bypass Model Installation<br />

STEP FIVE: Bypass Duct Installation<br />

1<br />

2<br />

On the duct opposite the humidifier Bypass install, cut<br />

a 6-in. diameter duct hole.<br />

• If the humidifier is on the supply duct, the 6-in.<br />

diameter hole should be on the return.<br />

• If the humidifier is on the return duct, the 6-in.<br />

diameter hole should be on the supply.<br />

Secure a 6-in. round duct starter collar into the 6-in.<br />

duct hole.<br />

MOUNTING<br />

MCR29933<br />

1<br />

2<br />

Use rigid or aluminized flexible 6-in. duct to connect<br />

the starter collar to the humidifier bypass port.<br />

Secure the duct to the humidifier port with self-drilling<br />

sheet metal screws using the pre-drilled holes on the<br />

bypass port. For added seal, wrap sheet metal tape<br />

around the duct to port connection point.<br />

2<br />

MCR29878<br />

Bypass mounting is complete. Go to page 11.<br />

Before proceeding to the next step:<br />

I secured the humidifier to the duct as instructed.<br />

<strong>Humidifier</strong> <strong>69</strong>-<strong>2413EF</strong>—<strong>01</strong> 9