CHIMNEY CAPS - DISTANCES AND POSITIONING UNI 10683/98<br />

Inclination of the<br />

roof<br />

Distance between the roof<br />

ridge and the stack<br />

Minimum height of the stack<br />

(measured from the outlet)<br />

α A (m) H (m)<br />

15°<br />

< 1.85 m 0.<strong>50</strong> m above the roof ridge<br />

> 1.85 m 1.00 m from the roof<br />

30°<br />

45°<br />

60°<br />

< 1.<strong>50</strong> m 0.<strong>50</strong> m above the roof ridge<br />

> 1.<strong>50</strong> m 1.30 m from the roof<br />

< 1.30 m 0.<strong>50</strong> m above the roof ridge<br />

> 1.30 m 2.00 m from the roof<br />

< 1.20 m 0.<strong>50</strong> m above the roof ridge<br />

> 1.20 m 2.60 m from the roof<br />

6. VENTILATION HOOD OR ADJACENT LOCAL<br />

The INSERTS <strong>Crystal</strong> <strong>70</strong> / <strong>80</strong> / <strong>100</strong> are pre-arranged for the connection of two additional ventilation outputs, by<br />

putting an OPTIONAL kit ventilation (centrifugal ventilator, art. Nr. 131<strong>80</strong>00, see Picture 12, Picture 13, Picture 15 –<br />

chapter 9)<br />

a) Perform the drilling on the walls or on the existing hood to allow the passage and the application of the (fireresistant)<br />

hoses with 15 cm diameter and related openings.<br />

b) Fasten the hoses using the clamps to the related collars and openings, after having removed the semi-blank caps.<br />

c) Each pipe must not exceed 1.5 m of length for natural ventilation and 4 m for forced ventilation; it must be<br />

insulated with insulating materials to avoid noise and dispersion of heat.<br />

d) The openings must be positioned at a height not lower than 2 m from the floor to avoid that hot air at output meets<br />

people.<br />

e) If the space between the upper part of the insert and the lower profile of the hood is lower than 10 cm, it is<br />

necessary to perform a hole of about 30 x 40 cm on the hood to allow the fastening of the hoses (see Picture 12 –<br />

Picture 13).<br />

f) The optional ventilation kit has to be installed below the appliance in the rear part (see instructions in chapter 9).<br />

As consequence you should arrange a underlying space to collocate it, allowing a proper air flow and the<br />

accessibility for future maintenance.<br />

SEMI-BLANKS<br />

Picture 12<br />

Picture 13 Picture 14<br />

<strong>INSERTO</strong> <strong>50</strong>V-<strong>p30</strong>: To ease the natural circulation of air (upward movement due to the heating of the same) in the<br />

external enclosure of the stack, it is necessary to remove the underlying semi-blanks. (see Picture 14).<br />

6096<strong>80</strong>1 – EN 21