INSERTO Crystal 50 - 50v - 50v p30 - 70 - 80 - 100 - ofenseite.com
INSERTO Crystal 50 - 50v - 50v p30 - 70 - 80 - 100 - ofenseite.com
INSERTO Crystal 50 - 50v - 50v p30 - 70 - 80 - 100 - ofenseite.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>INSERTO</strong> <strong>Crystal</strong> <strong>50</strong> – <strong>50</strong>v – <strong>50</strong>v <strong>p30</strong> – <strong>70</strong> – <strong>80</strong> – <strong>100</strong><br />
8. EXTERNAL AIR INTAKE<br />
For a good operation of the appliance, it is essential that a sufficient quantity of air for the <strong>com</strong>bustion and the reoxygenation<br />
of the room is introduced the installation room itself. This means that, through proper openings<br />
<strong>com</strong>municating with outside, the air for <strong>com</strong>bustion must circulate also with closed doors and windows.<br />
• The air intake must be positioned so that it cannot be obstructed.<br />
• Be <strong>com</strong>municating with the installation room of the appliance and be protected by grating.<br />
• Minimum surface must not be lower than 113 cm 2 .<br />
• Should the inflow of air be obtained by openings <strong>com</strong>municating with outside of nearby rooms, it is<br />
necessary to avoid air intakes in connection with garages, kitchens, bathrooms, thermal units (see<br />
Picture 17).<br />
• If in the local of installation there are inspiration hoods, these cannot work at the same time, as the<br />
contemporary use of them could cause the smoke exit in the room, even if the door is closed.<br />
(1) Insulating material<br />
(6) Heat drain grating<br />
(2) Seal<br />
(3) Insulating coating with external<br />
aluminum sheet<br />
(4) Door for cleaning<br />
(5) External air intake<br />
(7) Fire-retardant counter-hood<br />
(8) Maximum inclination 45°<br />
(9) Shield wooden parts with<br />
insulating material<br />
(10) Min. distance between Coating<br />
and insertsee MARKING INFORMATION<br />
Picture 17<br />
OPTIONAL<br />
For a better <strong>com</strong>fort and corresponding oxygenation of environment, the stove / insert <strong>com</strong>bustion air can be directly<br />
withdrawn at the outside. (Picture 18).<br />
6016040 - kit OPTIONAL - <strong>INSERTO</strong> <strong>Crystal</strong> <strong>50</strong> - <strong>50</strong>v - <strong>50</strong>v:<strong>p30</strong><br />
6016041 - kit OPTIONAL - <strong>INSERTO</strong> <strong>Crystal</strong> <strong>70</strong> - <strong>80</strong> - <strong>100</strong><br />
<strong>50</strong>v <strong>p30</strong><br />
Ø 120<br />
Picture 18<br />
160 mm <strong>INSERTO</strong> <strong>50</strong>v <strong>p30</strong><br />
200 mm <strong>INSERTO</strong> <strong>50</strong>-<strong>50</strong>v-<strong>70</strong>-<strong>80</strong>-<strong>100</strong><br />
6096<strong>80</strong>1 – EN 23