<strong>INSERTO</strong> <strong>Crystal</strong> <strong>50</strong> – <strong>50</strong>v – <strong>50</strong>v <strong>p30</strong> – <strong>70</strong> – <strong>80</strong> – <strong>100</strong><br />

8. EXTERNAL AIR INTAKE<br />

For a good operation of the appliance, it is essential that a sufficient quantity of air for the <strong>com</strong>bustion and the reoxygenation<br />

of the room is introduced the installation room itself. This means that, through proper openings<br />

<strong>com</strong>municating with outside, the air for <strong>com</strong>bustion must circulate also with closed doors and windows.<br />

• The air intake must be positioned so that it cannot be obstructed.<br />

• Be <strong>com</strong>municating with the installation room of the appliance and be protected by grating.<br />

• Minimum surface must not be lower than 113 cm 2 .<br />

• Should the inflow of air be obtained by openings <strong>com</strong>municating with outside of nearby rooms, it is<br />

necessary to avoid air intakes in connection with garages, kitchens, bathrooms, thermal units (see<br />

Picture 17).<br />

• If in the local of installation there are inspiration hoods, these cannot work at the same time, as the<br />

contemporary use of them could cause the smoke exit in the room, even if the door is closed.<br />

(1) Insulating material<br />

(6) Heat drain grating<br />

(2) Seal<br />

(3) Insulating coating with external<br />

aluminum sheet<br />

(4) Door for cleaning<br />

(5) External air intake<br />

(7) Fire-retardant counter-hood<br />

(8) Maximum inclination 45°<br />

(9) Shield wooden parts with<br />

insulating material<br />

(10) Min. distance between Coating<br />

and insertsee MARKING INFORMATION<br />

Picture 17<br />

OPTIONAL<br />

For a better <strong>com</strong>fort and corresponding oxygenation of environment, the stove / insert <strong>com</strong>bustion air can be directly<br />

withdrawn at the outside. (Picture 18).<br />

6016040 - kit OPTIONAL - <strong>INSERTO</strong> <strong>Crystal</strong> <strong>50</strong> - <strong>50</strong>v - <strong>50</strong>v:<strong>p30</strong><br />

6016041 - kit OPTIONAL - <strong>INSERTO</strong> <strong>Crystal</strong> <strong>70</strong> - <strong>80</strong> - <strong>100</strong><br />

<strong>50</strong>v <strong>p30</strong><br />

Ø 120<br />

Picture 18<br />

160 mm <strong>INSERTO</strong> <strong>50</strong>v <strong>p30</strong><br />

200 mm <strong>INSERTO</strong> <strong>50</strong>-<strong>50</strong>v-<strong>70</strong>-<strong>80</strong>-<strong>100</strong><br />

6096<strong>80</strong>1 – EN 23