TermoSovrana <strong>DSA</strong><br />

1. TECHNICAL DATA<br />

Definition: thermocooker in accordance with EN 12815<br />

<strong>TERMOSOVRANA</strong> – <strong>DSA</strong><br />

Overall thermal power in kW 16.6<br />

Useful thermal power in kW 13.5<br />

Output power to liquid (H 2 O) in kW 9<br />

Output power to room in kW 4.5<br />

Hourly wood consumption in kg / h (wood with 20% humidity) 3.9<br />

Yield 81.2<br />

CO measured at 13% oxygen in % 0.12<br />

Flue gas exhaust pipe diameter in mm<br />

Flue diameter in mm<br />

130 S/P<br />

5m – 220x220 Ø220∗<br />

Water contained in the boiler in litres 12<br />

Chimney pressure in (mm H 2 O) 1.7 – 2<br />

Delivery and return connector diameter (nominal bore)<br />

1”F gas<br />

External air intake section Ø in mm 200<br />

Exhaust gas emission in g/s – wood 17<br />

Exhaust gas temperature in °C - wood 172<br />

Optimum working temperature in °C 70 - 75<br />

Max. operating pressure in bar VEA 1,5 – VEC 3<br />

Furnace opening dimensions mm (W x H) 217 x 172<br />

Furnace body / furnace headpiece dimensions in mm (W x H x D) 257 x 250 x 395<br />

Oven dimensions in mm (W x H x D) 330 x 300 x 410<br />

Type of grill<br />

Movable - flat<br />

Thermocooker height in mm 889<br />

Thermocooker width in mm 964<br />

Thermocooker depth (with handles) in mm 640<br />

Weight in Kg 150<br />

Fire prevention safety distances Chapter 4<br />

∗ 200 mm diameter can be used with flue of no less than 6 m<br />

The heating volume of the cookers in accordance with EN 12815, for buildings whose thermal insulation does not<br />

correspond to the provisions regarding heat protection, is:<br />

(30 Kcal/h x m 3 ) - favourable type of building: 387 m³<br />

(40 Kcal/h x m 3 ) - less favourable type of building: 290 m³<br />

(50 Kcal/h x m 3 ) - unfavourable type of building: 232 m³<br />

With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater.<br />

With temporary heating, in the event of interruptions which last more than 8 hours, the heating capacity is reduced by<br />

about 25%.<br />

IMPORTANT: The power of the connected heating system must be proportional to the power transferred to<br />

the water by the thermocooker; a charge which is too low does not allow regular oven operation, while a<br />

charge which is too high prevents adequate radiator heating.<br />

20 7094211 Rev.03 – EN