TermoSovrana <strong>DSA</strong><br />
14.2. GLASS CLEANING<br />
Through a specific secondary air inlet, the formation of deposits of dirt, on the door glass, is effectively slowed down.<br />
It cannot, though, ever be avoided with the use of solid fuels (e.g. damp wood) and this should not be considered a<br />
defect of the appliance.<br />
IMPORTANT: the cleaning of the panoramic glass must only be carried out when the thermocooker is cold, in<br />
order to prevent it exploding. Do not use cloths or products which are abrasive or chemically aggressive.<br />
The correct lighting phase, the use of proper quantities and types of fuels, the correct position of the secondary air<br />
regulator, enough draught of the chimney-flue and the presence of combustion air are the essential elements for the<br />
optimal functioning of the appliance and for the cleaning of the glass.<br />
GLASS BREAKAGE: as the glass parts are in ceramic glass, resistant up to a sudden thermal change of<br />
750°C, they are not subject to thermal shocks. Thei r breakage can only be caused by mechanical shocks<br />
(knocks or violent door closing etc.). Therefore replacement is not covered by the warranty.<br />
14.3. ASH DRAWER CLEANING<br />
All LA NORDICA thermocookers have a furnace grill and a drawer for ash<br />
collection. It is advisable to empty the ash drawer periodically and prevent it<br />
filling up completely, so as not to overheat the grill. In addition, it is<br />
advisable to always leave 3-4 cm of ash in the furnace.<br />
CAUTION: the ash removed from the furnace must be replaced in a<br />
recipient for fireproof material equipped with an airtight cover. The<br />
recipient must be placed on fireproof flooring, away from flammable<br />
materials until the ash is completely out and cool.<br />
IMPORTANT: if for whatever reason the grill is removed from the furnace,<br />
take care to reassemble it with the wider part of the slit facing<br />
downwards. This is to aid furnace cleaning (Picture 13).<br />
Picture 13<br />
14.4. MAINTENANCE ON THE WATER SYSTEM<br />
With the system switched off, once a year carry out the following checks:<br />
• Check the operation and efficiency of the blowdown and safety valves. If they are defective, contact your<br />
authorised installer. IT IS STRICTLY FORBIDDEN TO REMOVE OR TAMPER WITH THE SAFETY<br />
DEVICES.<br />
• Check the thermal insulation of the filling pipe and the safety pipe.<br />
• Make sure that the system is filled and under pressure, checking the water level in the expansion tank; also<br />
check that it is working properly and check the efficiency of the safety pipe.<br />
15. SUMMER SET ASIDE<br />
WARNING: The system should be kept constantly full of water even in periods in which the use of the wood burning<br />
stove/cooker is not required. During the winter, inactivity must be faced with the addition of antifreeze.<br />
After having cleaned the furnace, the chimney and the flue, ensuring total elimination of the ash and other residues,<br />
close all the furnace doors and respective registers and disconnect the appliance from the chimney.<br />
It is advisable to carry out the flue cleaning operation at least once a year; in the meantime, check that the seals are<br />
in good condition as, if not perfectly intact, they do not guarantee good appliance operation! In this case, it is<br />
necessary to replace them.<br />
If appearance is to be maintained over time, protect the cast iron parts with neutral Vaseline.<br />
16. CONNECTING A FIREPLACE OR OPEN HEARTH TO THE FLUE<br />
The flue gas channel is the stretch of piping which connects the thermoproduct to the flue. In the connection, these<br />
simple but extremely important principles must be respected:<br />
• under no circumstances use a flue gas channel with a diameter less that that of the exhaust clamp with which<br />
the thermoproduct is equipped;<br />
• each metre of the horizontal stretch of the flue gas channel causes a slight loss of head which must be<br />
compensated if necessary by elevating the flue;<br />