1<br />

6 Electrical connection<br />

Connection type A (ecoMAX):<br />

Connect the overflow safety switch to the boiler‘s low<br />

voltage circuit in the following manner:<br />

• Open the boiler electrical box.<br />

• Remove the cable bridge from the blue slot (“Anl-<br />

Therm”) on the circuit board.<br />

• Plug the blue Pro E plug on the end of the <strong>ecoLEVEL</strong><br />

condensate cable into this slot.<br />

13<br />

Codierwiderstand<br />

X 2<br />

1 1 1<br />

X 10 X 7 X 8<br />

1<br />

Anl -<br />

Therm<br />

2<br />

24V I<br />

230V<br />

7 8 9 L N 3 4 5 L N<br />

RT 24V 230V RT 230V<br />

L N<br />

Pumpe 2. Pumpe<br />

Fig. 6.2 Connecting the overflow safety switch, connection<br />

type A<br />

8 Installation and maintenance manual <strong>ecoLEVEL</strong>