Domestic Hot Water - Follow operational sequence<br />

Turn selector to<br />

neon illuminated<br />

YES<br />

NO<br />

Go to section ‘A’<br />

Is mains water filter and differential<br />

assembly clean?<br />

YES<br />

Replace diaphragm<br />

YES<br />

DHW flow valve diaphragm<br />

damaged<br />

Turn thermostat to max.<br />

Open DHW tap fully. DHW<br />

flow switch operated<br />

NO<br />

YES<br />

DHW flow rate more than<br />

2.5l/min.<br />

NO<br />

DHW flow valve rod<br />

obstructed<br />

YES<br />

Primary water is diverted<br />

from CH system to DHW heat<br />

exchanger and flow microswitch<br />

operated<br />

neon illuminated<br />

NO<br />

Continuity across DHW flow<br />

microswitch terminals and<br />

PCB - A5 connector terminals<br />

5 & 6<br />

NO<br />

YES<br />

Replace DHW flow microswitch<br />

Replace PCB<br />

YES<br />

Pump runs<br />

YES<br />

NO<br />

neon flashing<br />

Go to section ‘B’<br />

Primary flow switch operated<br />

YES<br />

Fan runs at max speed<br />

YES<br />

NO<br />

NO<br />

neon flashing<br />

Go to section ‘C’<br />

neon flashing<br />

NO<br />

neons flashing<br />

YES<br />

Turn selector to reset position.<br />

If regular resetting is<br />

required or appliance still<br />

does not operate investigation<br />

is necessary<br />

Go to section ‘J’<br />

Go to section ‘D’<br />

Air pressure switch proved<br />

NO<br />

neon flashing<br />

Go to section ‘E’<br />

YES<br />

Spark at ignition electrodes<br />

for up to 10 seconds<br />

YES<br />

NO<br />

NO<br />

Replace PCB<br />

neon flashing<br />

NO<br />

YES<br />

Turn the selector to the reset<br />

position. If the light does not<br />

extinguish go to section H &<br />

K<br />

neon illumina-<br />

Burner on<br />

ted<br />

Go to section ‘F’<br />

YES<br />

Burner extinguishes<br />

after 10 seconds<br />

NO<br />

YES<br />

neon flashing<br />

Go to section ‘I’<br />

Burner output modulates to<br />

maintain temperature set at<br />

thermostat<br />

YES<br />

Close DHW tap<br />

YES<br />

DHW flow valve senses no<br />

flow.<br />

Primary water diverted to CH<br />

system. DHW flow switch<br />

released off<br />

YES<br />

Burner goes out<br />

NO<br />

NO<br />

Reduce the DHW flow rate.<br />

If burner does not modulate<br />

clean DHW temperature<br />

sensor and DHW heat<br />

exchanger. If modulation<br />

does not occur go to section<br />

‘G’<br />

Diverter valve spindle assembly<br />

faulty<br />

NO YES YES<br />

Fan stops<br />

Pump stops<br />

36<br />

Operation sequence correct