User Instructions - English5.6 Options for Terminating Cable in the Fieldfor increased versatility during installation to accommodatevariable cable lengths. These options are compatiblewith 3/8” diameter approved cable only.Thimble and Wire RopeCable Termination Kit (VGTWC)1. Feed cable around cable thimble, turning back 5-1/4" of cable fromthimble end. dead end of rope. Use torque wrench to tighten evenly, alternatingfrom one nut to the other until reaching a torque of 45 ft. lbs.2. Install second cable clip as close to the thimble as possible. Again,use torque wrench to tighten evenly to 45 ft. lbs.1 Clip Base Width (1-1/8")from Dead EndDead EndCompletely AssembledLive EndFast-Attach Fitting for 3/8” Diameter Approved Cable (VGF-1)*Wedge Set includes three toothedwedges and retaining ring.13