MENU DESCRIPTION0.5dB)PAGE 21ENGLISH1.4 Mute/SoloAllows the user to switch the function of the front panelchannel buttons between Mute and solo mode.Individual channel muting is made in the DSP processoritself. However, when all 4 MUTE buttons are active theoutput relays bypass the circuitry, to eliminate any residualnoise.1.5 SAVE Set-upIt is possible to store and recall up to 10 user set-ups butexcluding MUTE BUTTONS STATE.Additionally the current set-up is saved in case of powerfailure every two minutes after the last change. At power upthis set-up is restored.Set-ups are numbered from 1 to 10. When saving your setupyou can choose a reference name up to 6 characters foridentification purposes.NOTE: ALL SAVED SETUPS WILL BE ERASED WHENDOWNLOADING A NEW VERSION OF THESOFTWARE.1.6 RECALL Set-upRecalling a user set-up is forbidden if the family of cabinetis not the same.When recalling a set-up, the unit will stay in the recall menuallowing another selection for comparison. Switching from aset-up to another is glitch-free and instantaneous (nomuting takes place).1.7 Array EQOne array EQ gain control of +/- 6dB (0.5dB step) isincluded. This filter frequency is factory tuned.10.000AlphaTD Controller Array EQ / Frequency (Hz) / Gain (dB)8.00006.00004.00002.00000.0-2.000-4.000-6.000-8.000-10.0020 100 1k 10k 20kUSER MANUAL LOAD2_22DATE: 03/12/2004