6. Carry out the electrical installation as follows:<br />

Installation<br />

• Install the machine in accordance with installation category CAT II.<br />

• Make a notch for electrical cables on the side of the machine.<br />

• In the opening, fit the cable gland supplied and pull the cables through.<br />

• Connect the machine to a separate isolator switch approved to local<br />

standards. The isolator must be mounted on the wall close to the<br />

machine.<br />

• Connect to protective earth and to the supply voltage stated on the type<br />

plate. Check that the connection has suitable overcurrent protection.<br />

The correct fuse rating is stated on the type plate.<br />

• All cables must be classified for at least 90 °C.<br />

Variant Electrical connection Fuse Power<br />

req.<br />

L1 220-230 V, 1N+PE 50 Hz (TN) 1x16 A 3.0 kW<br />

L2 230 V, 3+PE 50 Hz 3x16A 4.0 kW<br />

L3 380-400 V, 3N+PE 50 Hz (TN) 3x10 A 4.0 kW<br />

V2 220-230 V, 1N+PE 50 Hz (TN) 1x10 A 1.0 kW<br />

L5 240 V, 2+PE 60 Hz (TN) 2x15 A 3.6 kW<br />

V3 240 V, 2+PE 60 Hz (TN) 2x10 A 1.4 kW<br />

L9 208 V, 2+PE 60 Hz (TN) 2x15 A 3.0 kW<br />

L10 208 V, 3+PE 60 Hz (TN) 3x15 A 3.8 kW<br />

V4 208 V, 2+PE 60 Hz (TN) 2x10 A 1.4 kW<br />

L14 200 V, 2+PE 50 Hz (TN) 2x16 A 3.0 kW<br />

L15 200 V, 3+PE 50 Hz (TN) 3x16A 4.0 kW<br />

L18 200 V, 2+PE 60 Hz (TN) 2x16 A 3.4 kW<br />

L19 200 V, 3+PE 60 Hz (TN) 3x16 A 4.4 kW<br />

L22 220-230 V, 1N+PE 60 Hz (TN) 1x16 A 3.4 kW<br />

L24 380-400V, 3N+PE 60 Hz (TN) 3x10 A 4.4 kW<br />

7. Environmental requirements, sound level and weight:<br />

Air humidity max 80 % at 31°C<br />

Room temperature 5-40°C<br />

Sound level 60 dB(A)<br />

Weight Free-standing = 90 kg, under-bench = 105 kg<br />

8. Steam<br />

Connection 15 (1/2") mm<br />

Pressure 30-300 kPa<br />

Consumption 0,3kg/process<br />

4 Edition 050625 5014907-00 Rev A