2.2.2 Loading the sand <strong>AR</strong>-140 / <strong>AR</strong>-140E / <strong>AR</strong>-140E<br />

• Cover the opening of the inner collector tube with protective plastic in order to prevent sand from entering the tube<br />

(Fig. 5 B).<br />

• Place the inner collector properly on the bottom of the filter (Fig. 6).<br />

• Place the collector in a way that the main drain pipe (Pos. B, Fig. 7 ), fits the hole of the lower side of the valve<br />

(Pos. A, Fig. 7 ). This tube (B) is used to extract the air that could be in the collector (Fig. 7).<br />

• Insert ONLY 85 Kg of sand inside the filter (fig. 5 B). Sand is delivered in 25 kg. sacks.<br />

• The silica sand lasts for an be replaced if lost. Record the reference for the level of silica sand for future replacement.<br />

• Eliminate the remains of sand from the filter opening and remove the protective plastic.<br />

• Replace the TOP selector valve with its coupling and secure with the metal band or seal .<br />

• Tighten firmly the screw (Pos. 6 Fig.4 ) on the metal band which joins the valve to the filter.<br />

2.2.3 Connecting the hoses<br />

models <strong>AR</strong>-<strong>135</strong> / <strong>AR</strong>-<strong>135</strong>L / <strong>AR</strong>-<strong>135</strong>E / <strong>AR</strong>-140 / <strong>AR</strong>-140L / <strong>AR</strong>-140E<br />

•= Place a coupling inside the return connection of the selector valve and tighten the 1½” sleeve firmly. (Fig. 8 and 14).<br />

•= Connect one end of the ø38 mm x 4.5 m. hose to the sleeve, fastening firmly with the clamp (Fig. 8). Connect the<br />

other end of this hose to the return nozzle in the pool using a clamp.<br />

•= Take the other ø38 mm x 4.5 m. hose and connect one end to the skimmer outlet using a clamp. To connect the<br />

other end of this hose, follow the instructions given below depending on the model of pump supplied.<br />

2.2.4 Assembling the pump<br />

•= First check which model of pump is supplied with the equipment and follow the corresponding instructions.<br />

2.2.4.1 Model with Minipump (Fig. 9)<br />

•= Screw the 1 ¼ sleeve (Pos. 15 Fig. 9) with teflon in the suction connection of the pump and then connect the other<br />

end of the ø38 mm x 4.5 m. hose from the skimmer to this sleeve, tightening it firmly with a clamp (Pos.10 Fig. 9).<br />

•= Place a coupling (Pos.13 Fig. 9) inside the pump drive connection and screw the 1” sleeve (Pos.14 Fig. 9). Unless it<br />

is already connected, connect to this sleeve using a clamp on one end of the (<strong>AR</strong>-<strong>135</strong> = ø38 mm x 0.58 m // <strong>AR</strong>-140 =<br />

ø38 mm x 0.68 m) (Pos.8 Fig. 9) hose and connect the other end to the 1 ½ sleeve (Pos. 12 Fig. 8) at the inlet of the<br />

selector valve (that has previously been set in the PUMP position) and tighten with a clamp.<br />

2.2.4.2 Model with Compact pump (Fig. 15)<br />

•= Now connect the other end of the ø38 mm x 4.5 m. hose that comes from the skimmer to the suction cover of the<br />

pump, fastening it firmly with the clamp (Fig. 15).<br />

•= Place the O-ring (Pos. 19 Fig. 15) in the pump drive connection.<br />

•= Insert the drive sleeve (Pos.18 Fig. 15) through the nut (Pos.17 Fig. 15) and fully screw the nut to the pump drive<br />

connection.<br />

•= Connect one end of the (<strong>AR</strong>-<strong>135</strong> = ø38 mm x 0.58 m // <strong>AR</strong>-140 = ø38 mm x 0.68 m) (Pos.8 Fig. 15) hose to the 1 ½”<br />

inlet sleeve (Pos.12 Fig. 14) of the selector valve (that has previously been set in the PUMP position) and fully tighten<br />

with a clamp. Connect the other end to the pump drive connection (Pos.18 Fig. 15) and tighten with a clamp.<br />

2.2.5 Assembly the pressure gauge<br />

WITHOUT<br />

PRESSURE GAUGE<br />