Tabella di scelta - Table of choices<br />
1 hour duration<br />
Model Voltage Lamp Battery Flux ratio Autonomy Batt. current Weight<br />
ER 1831 230/240V - 50/60Hz 18W 3,6V-1,5Ah 10% 1h 1A 370g -<br />
ER 3641 230/240V - 50/60Hz 18 - 36W 4,8V-1,5Ah 12-8% 1h 1 - 1,1A 430g -<br />
ER 5834 230/240V - 50/60Hz 18 - 58W 3,6V-4Ah 15-7% 1h 1,5 - 2,4A 620g -<br />
ER 5844 230/240V - 50/60Hz 18 - 58W 4,8V-4Ah 18-9% 1h 1,3 - 2A 750g -<br />
3 hour duration<br />
Model Voltage Lamp Battery Flux ratio Autonomy Batt. current Weight<br />
ER 5844/3 230/240V - 50/60Hz 18 - 58W 4,8V-4Ah 12 - 6% 3h 1 - 1,2A 750g -<br />
Fattore % del flusso luminoso in emergenza - Emergency Ballast Lumen Factor (BLF) in %<br />
ER1831 ER3641 ER5834 ER5844 ER5844/3<br />
T5<br />
4 W lin G5 1h 20% 1h 19% 3h 28% 2h 30% 4h 19%<br />
6 W lin G5 1h 18% 1h 16% 3h 24% 2h 26% 4h 16%<br />
8 W lin G5 1h 18% 1h 16% 3h 24% 2h 26% 4h 16%<br />
13 W lin G5 1h 15% 1h 15% 2h 20% 2h 22% 3h 15%<br />
T8<br />
18 W lin G13 1h 10% 1h 12% 2h 15% 2h 18% 3h 12%<br />
36 W lin G13 1h 8% 1,5h 10% 1,5h 12% 3h 8%<br />
58 W lin G13 1h 7% 1h 7% 1h 9% 3h 6%<br />
T8C<br />
22 W circ G10q 1h 11% 2h 16% 2h 17% 3h 11%<br />
32 W circ G10q 1h 8% 1,5h 12% 2h 13% 3h 8%<br />
2D<br />
10 W 2D GR10q 1h 18% 1h 16% 2h 25% 2h 28% 3h 16%<br />
16 W 2D GR10q 1h 13% 1h 12% 2h 18% 2h 20% 3h 12%<br />
28 W 2D GR10q 1h 11% 1,5h 15% 2h 17% 3h 11%<br />
38 W 2D GR10q 1,5h 10% 1,5h 11% 3h 8%<br />
TC-S/E<br />
5 W comp 2G7 1h 22% 1h 19% 3h 30% 2h 33% 4h 19%<br />
7 W comp 2G7 1h 18% 1h 16% 3h 25% 2h 28% 4h 16%<br />
9 W comp 2G7 1h 18% 1h 16% 3h 25% 2h 28% 4h 16%<br />
11 W comp 2G7 1h 15% 1h 12% 2h 20% 2h 22% 3h 12%<br />
TC-D/E<br />
10 W comp G24q 1h 15% 1h 12% 2h 20% 2h 22% 3h 12%<br />
13 W comp G24q 1h 15% 1h 12% 2h 20% 2h 22% 3h 12%<br />
18 W comp G24q 1h 10% 1h 12% 2h 15% 2h 18% 3h 12%<br />
26 W comp G24q 1h 9% 2h 15% 2h 17% 3h 9%<br />
TC-L<br />
18 W comp 2G11 1h 10% 1h 12% 2h 15% 2h 18% 3h 12%<br />
24 W comp 2G11 1h 11% 2h 16% 2h 17% 3h 11%<br />
36 W comp 2G11 1h 8% 1,5h 10% 1,5h 12% 3h 8%<br />
55 W comp 2G11 1h 9% 1h 9% 3h 6%<br />
TC-F<br />
18 W comp 2G10 1h 10% 1h 12% 2h 15% 2h 18% 3h 12%<br />
24 W comp 2G10 1h 11% 2h 16% 2h 17% 3h 11%<br />
36 W comp 2G10 1h 8% 1,5h 10% 1,5h 12% 3h 8%<br />
TC-T/E<br />
32 W comp Gx24q 1h 8% 1,5h 10% 1,5h 11% 3h 8%<br />
42 W comp Gx24q 1h 7% 1h 8% 2h 7%<br />
La Serie ER può essere utilizzata anche per lampade T5. La Serie C e la Serie T sono consigliate per ottenere una migliore<br />
resa luminosa e prevenire la migrazione del mercurio, causa dell'arrossamento della lampada<br />
ER Series could be used for T5 lamps. We advice to use Series C and Series T to prevent "mercury migration", which causes<br />
the lamp to go red, and enhance light yield, while prolonging the life of the lamp.<br />
ER1831 ER3641 ER5834 ER5844 ER5844/3<br />
T5<br />
14 W HE/FH G5 1h 9% 1h 7% 2h 11% 2h 14% 3h 6%<br />
21 W HE/FH G5 1h 11% 1h 14% 3h 6%<br />
28 W HE/FH G5 1h 11% 1h 12% 3h 5%<br />
35 W HE/FH G5 1h 9% 1h 11%<br />
24 W HO/FQ G5 1h 6% 2h 8% 2h 10% 3h 5%<br />
39 W HO/FQ G5 1h 6% 1h 8% 3h 8%<br />
49 W HO/FQ G5 1h 3% 1h 5%<br />
54 W HO/FQ G5 1h 6% 1h 8%<br />
80 W HO/FQ G5 1h 5%<br />