Manual de Instalación y Mantenimiento - Ferromar
Manual de Instalación y Mantenimiento - Ferromar
Manual de Instalación y Mantenimiento - Ferromar
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
FROMPOOLFILTERCELLPOOLRETURNSFROMPOOLFILTERHEATERCELLPOOLRETURNSBY-PASS1Assembly graphicThe control panel must be installed close to the water filteringsystem. The i<strong>de</strong>al location is on a wall offering protection against rainfall,splashing or acci<strong>de</strong>ntal overflow.Note: The housing of the cell is adapted for pipes of 50 mmPlease ensure that the cable from the control panel is correctly attachedto the cell in accordance with the colour coding.Place the control panel higher than the cell but not more than 1 meteraway so as not to stretch the cable between the panel and the cell. Similarly, itcan be placed upright on the ground.Do not install the cell above the pump. Place it in the water return circuitor returns pipes.20