TRASFORMATORE DI CORRENTE TIPO AD UN NUCLEO<br />

SINGLE CORE CURRENT TRANSFORMER<br />

24 kV<br />

Modello<br />

Type<br />

CTA 24-11<br />

Caratteristiche CARATTERISTICHE standard STANDARD<br />

- Isolamento a secco in resina - Funzionamento all’interno<br />

- Installazione esposta<br />

- Installazione anche in clima tropicale<br />

- Tensione di riferimento per l’isolamento 24 kV<br />

- Tensione di prova a freq. industriale e ad impulso 50/125 kV<br />

- Frequenza 50 Hz oppure 60 Hz<br />

- Corrente nominale secondaria 5 A oppure 1 A<br />

- Corrente nominale termica di c.to c.to (Ith) 100 Ipn /1”- max 60 kA<br />

- Corrente nominale dinamica (Idyn) 2,5 Ith<br />

- Costruzione in accordo alle norme IEC 61869-1/2<br />

- Coprimorsetti sigillabile sul secondario<br />

ESECUZIONI Esecuzioni REALIZZABILI realizzabili a A richiesta RICHIESTA<br />

- Corrente nominale secondaria diversa da 1 A e 5 A<br />

- Costruzione in accordo alle norme VDE ,BS ,ANSI<br />

- Rapporti e prestazioni diversi da quelli indicati<br />

- Corrente nominale di c.to c.to superiori a 100 Ipn/1” max 60 kA<br />

- Presa capacitiva<br />

<br />

Peso kg 25 circa – Weight kg 25 abt.<br />

features FEATURES standard STANDARD<br />

- Dry insulation in resin – Indoor installation<br />

- Exposed installation<br />

- Indoor installation also in tropics<br />

- Highest system voltage up to 24 kV<br />

- Test voltage (1’/50Hz) and impulse voltage 50/125 kV<br />

- Frequency 50 Hz or 60 Hz<br />

- Normal secondary rated 5 A or 1 A<br />

- Rated short-time thermal current (Ith) 100 Ipn/1” max 60 kA<br />

- Rated dynamic current (Idyn) 2,5 Ith<br />

- Transformers accord<strong>ing</strong> to IEC 61869-1/2<br />

- Sealable protection on the secondary<br />

Special SPECIAL executions EXECUTIONS on ON request REQUEST<br />

- Rated secondary current different from 1 A and 5 A<br />

- Transformers accord<strong>ing</strong> to VDE ,BS ,ANSI<br />

- Different burdens from the ones indicated<br />

- Rated short-time thermal current different from 100 Ipn/1” max 60 kA<br />

- Capacitive voltage tap<br />

Dimensioni d’<strong>ing</strong>ombro ( mm ) - Outline dimensions ( mm )<br />

Fig. 1<br />

Posizione piastrine di commutazione<br />

Position of commutat<strong>ing</strong> links<br />

Targa dati<br />

Rat<strong>ing</strong> plate<br />

Fig. 2<br />

Collegamento<br />

serie<br />

Series<br />

Collegamento<br />

parallelo<br />

Parallel<br />

sez. B - - pag. 33 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!