TRASFORMATORE DI DI TENSIONE AD UN AD POLO UN POLO PRIMARIO PRIMARIO<br />
SINGLE SINGLE POLE POLE VOLTAGE VOLTAGE TRANSFORMER<br />
24 kV 24 kV<br />
Modello Modello<br />
Type Type<br />
DTY DTY 20 20<br />
Caratteristiche CARATTERISTICHE standard STANDARD STANDARD<br />
- Inserzione - Inserzione tra fase tra e fase terra e terra<br />
- Isolamento - Isolamento a secco a secco in resina resina - - Funzionamento all’interno all’interno<br />
- Installazione - Installazione esposta esposta<br />
- Installazione - Installazione anche anche in clima in clima tropicale tropicale<br />
- Uno - o Uno due o rapporti due rapporti primari, primari, ottenuti ottenuti con presa con presa sul secondario sul secondario<br />
- Tensione - Tensione di riferimento di riferimento per l’isolamento per l’isolamento 24 kV 24 kV<br />
- Tensione - Tensione di prova di prova a freq. a industriale freq. industriale e ad impulso e ad impulso 50/125 50/125 kV kV<br />
- Frequenza - Frequenza 50 Hz 50 oppure Hz oppure 60 Hz 60 Hz<br />
- Fattore - Fattore di tensione di tensione nominale nominale : 1,2 continuativo : 1,2 continuativo / 1,9 x / 1,9 8 h x 8 h<br />
- Potenza - Potenza termica termica nominale nominale 400 VA 400 VA<br />
- Costruzione - Costruzione in accordo in accordo alle norme alle norme IEC 61869-1/3 IEC 61869-1/3<br />
- Coprimorsetti - Coprimorsetti sigillabile sigillabile sul secondario sul secondario<br />
Esecuzioni ESECUZIONI realizzabili REALIZZABILI a A richiesta RICHIESTA<br />
A RICHIESTA<br />
- Tensione - Tensione nominale nominale secondaria secondaria diversa diversa da quelle da quelle indicate indicate<br />
- Costruzione - Costruzione in accordo in accordo alle norme alle norme VDE ,BS VDE ,ANSI ,BS ,ANSI<br />
- Due - avvolgimenti Due avvolgimenti secondari secondari<br />
- Prestazioni - Prestazioni diverse diverse da quelle da quelle indicate indicate<br />
<br />
<br />
Peso kg Peso 32 kg circa 32 circa – Weight – Weight kg 32 kg abt. 32 abt.<br />
features FEATURES FEATURES standard STANDARD STANDARD<br />
- Insertion - Insertion between between phase phase and earth and earth<br />
- Dry - insulation Dry insulation resin resin – Indoor – Indoor installation installation<br />
- Exposed - Exposed installation installation<br />
- Indoor - Indoor installation installation also in also tropics in tropics<br />
- S<strong>ing</strong>le - S<strong>ing</strong>le or double or double primary primary ratios ratios by secondary by secondary reconnection reconnection<br />
- Highest - Highest system system voltage voltage up to up 24 to kV 24 kV<br />
- Test - voltage(1’/ Test voltage(1’/ 50 Hz) 50 and Hz) impulse and impulse voltage voltage 50/125 50/125 kV kV<br />
- Frequency - Frequency 50 Hz 50 or Hz 60 or Hz 60 Hz<br />
- Rated - Rated voltage voltage factor factor : 1,2 continuous : 1,2 continuous / 1,9 x / 81,9 h x 8 h<br />
- Rated - Rated thermal thermal duty 400 duty VA 400 VA<br />
- Transformers - Transformers accord<strong>ing</strong> accord<strong>ing</strong> to IEC to 61869-1/3 IEC 61869-1/3<br />
- Sealable - Sealable protection protection on the on secondary the secondary<br />
Special SPECIAL SPECIAL executions EXECUTIONS on request REQUEST ON REQUEST<br />
- Different - Different rated rated secondary secondary voltage voltage from the from ones the indicated ones indicated<br />
- Transformers - Transformers accord<strong>ing</strong> accord<strong>ing</strong> to VDE to ,BS VDE ,ANSI ,BS ,ANSI<br />
- Two - secondary Two secondary wind<strong>ing</strong>s wind<strong>ing</strong>s<br />
- Different - Different burdens burdens from the from ones the indicated ones indicated<br />
Dimensioni Dimensioni d’<strong>ing</strong>ombro d’<strong>ing</strong>ombro ( mm () mm - Outline ) - Outline dimensions dimensions ( mm ()<br />
mm )<br />
pag. 86 - sez. R<br />
sez. sez. R - R pag. - pag. 6 6