TRASFORMATORE DI TENSIONE AD UN POLO PRIMARIO<br />

SINGLE POLE VOLTAGE TRANSFORMER<br />

36 kV<br />

Modello<br />

Type<br />

CTY 36<br />

Caratteristiche CARATTERISTICHE standard STANDARD<br />

- Inserzione tra fase e terra<br />

- Isolamento a secco in resina - Funzionamento all’interno<br />

- Installazione esposta<br />

- Installazione anche in clima tropicale<br />

- Uno o due rapporti primari, ottenuti con presa sul secondario<br />

- Tensione di riferimento per l’isolamento 36 kV<br />

- Tensione di prova a freq. industriale e ad impulso 70/170 kV<br />

- Frequenza 50 Hz oppure 60 Hz<br />

- Fattore di tensione nominale : 1,2 continuativo / 1,9 x 8 h<br />

- Potenza termica nominale 500 VA<br />

- Costruzione in accordo alle norme IEC 61869-1/3<br />

- Coprimorsetti sigillabile sul secondario<br />

ESECUZIONI Esecuzioni REALIZZABILI realizzabili a A richiesta RICHIESTA<br />

- Tensione nominale secondaria diversa da quelle indicate<br />

- Costruzione in accordo alle norme VDE ,BS ,ANSI<br />

- Due avvolgimenti secondari<br />

- Prestazioni diverse da quelle indicate<br />

<br />

Peso kg 56 circa – Weight kg 56 abt.<br />

Dimensioni d’<strong>ing</strong>ombro ( mm ) - Outline dimensions ( mm )<br />

features FEATURES standard STANDARD<br />

- Insertion between phase and earth<br />

- Dry insulation in resin – Indoor installation<br />

- Exposed installation<br />

- Indoor installation also in tropics<br />

- S<strong>ing</strong>le or double primary ratios by secondary reconnection<br />

- Highest system voltage up to 36 kV<br />

- Test voltage(1’/ 50 Hz) and impulse voltage 70/170 kV<br />

- Frequency 50 Hz or 60 Hz<br />

- Rated voltage factor : 1,2 continuous / 1,9 x 8 h<br />

- Rated thermal duty 500 VA<br />

- Transformers accord<strong>ing</strong> to IEC 61869-1/3<br />

- Sealable protection on the secondary<br />

Special SPECIAL executions EXECUTIONS on ON request REQUEST<br />

- Different rated secondary voltage from the ones indicated<br />

- Transformers accord<strong>ing</strong> to VDE ,BS ,ANSI<br />

- Two secondary wind<strong>ing</strong>s<br />

- Different burdens from the ones indicated<br />

pag. 90 - sez. R<br />

sez. R - pag. 10