Parameter<br />
Value<br />
SCI-section size aprox. 100<br />
SCI-section size min 60<br />
Resistivity [m]<br />
Auto scale or hom<strong>og</strong>enous half space<br />
Thickness [m] 15, 30, 50, 65<br />
Vertical constraints, resistivities<br />
99 (not constrained)<br />
Horizontal constraints, resistivities 1.5<br />
Horizontal constraints, thicknesses<br />
99 (not constrained)<br />
Horizontal constraints, depths 1.7, 1.2, 1.11, 1,06<br />
Auto scaling, power 0.75<br />
<br />
<br />
Parameter<br />
SCI-section size aprox. 35<br />
SCI-section size min 25<br />
Resistivity [m]<br />
Number of layers<br />
Thickness first layer [m] 1<br />
Thickness A-priori constraint 2<br />
Vertical constraints, resistivities 2<br />
Value<br />
Horizontal constraints, resistivities 1.5<br />
Horizontal constraints, thicknesses 2<br />
Horizontal constraints, depths<br />
Auto scaling, power 0.75<br />
Auto scale or hom<strong>og</strong>enous half space<br />
19 (maximum number)<br />
4 m followed by l<strong>og</strong>arithmic increasing thicknesses<br />
1.001 (fixed)<br />
99 (not constrained)<br />
99 (not constrained)<br />
1 Last layer boundary is chosen so it covers the expected depth of investigation.