Exercícios<br />

Calcule a taxa de dose no ar a 1,99 metros de uma fonte de<br />

Co-60 de 50 Ci de atividade blindada por 10 mm de<br />

chumbo, considerando a situação de boa geometria.<br />

Solução:<br />

Γ - 1,32 (R.m 2 /(Ci.h)<br />

µchumbo (E = 1,25 MeV) = 0,646 cm -1<br />

Empregando o conceito de camada semi-redutora,<br />

X = Γ.A 2 -n /d 2<br />

CSR =ln2/ µ = 0,693/µ = 0,693/0,6458 = 1,07 cm<br />

n = 1/1,07 =0,93<br />

X = 1,32*50*2 -0,93 /2 2 = 8,66 R/h<br />

D = 8,66 . 0,869 = 7,52 rad/h,<br />

D = 0,0752 Gy/h = 75,2 mSv/h