<strong>DIRIS</strong> <strong>A40</strong> /<strong>A41</strong>CARACTÉRISTIQUES TECHNIQUESTECHNICAL CHARACTERISTICS - TECHNISCHE DATEN -CARATTERISTICHE TECNICHE - TECHNISCHE EIGENSCHAPPEN -CARACTERÍSTICAS TÉCNICAS - CARACTERÍSTICAS TÉCNICASGBCONFORMITE IEC 61557-12 Edition 1 (08/2007)CARACTÉRISTIQUES DU PMDType of specification Examples of possible specification values Other additionalspecificationsSupply quality evaluationfunction (optional)- -PMD classification SD -Setpoint K55 -Humidity + Altitude - -Operating performanceclass for active power oractive energy (if functionavailable)0,5 -CARACTÉRISTIQUES DES FONCTIONSSymbols for functions Measurement range Operating performance class,according to CEI 61557-12Other additionalspecificationsKI 1000 100 10 1P - 0,5 - - 2 from -90° to +90°Qa, Qv - 1 - - 2 -Sa, Sv - 1 - - - -Ea0 to 99999999 kW/hfrom 0,02 to 1,2 In with PF =0,5 - - -0,5L or 0,8CEra, Erv0 to 99999999 kVar/hfrom 0,1 to 1,2 In with sin =1 - - -0,5 L or CEapa, Eapv 0 to 99999999 kW/h 0,5 - - - -f 45 to 65 Hz 0,02 - - - -I0,1 to 1,2 A for TC 1Afrom 10 to 110% / In ( In = 10,2 - - -0,5 to 6 A for TC 5Aor 5A according to CT )In, Inc0,1 to 1,2 A for TC 1A0,5 to 6 A for TC 5A0,2 - - -10 to 110% / In ( In = 1 or 5Aaccording to CT )U 50 to 600 V (phase/phase) 0,2 - - - -PFa ,PFv - 0,5 - - - pour 0,5< PF