Mjukvara set-up procedur<br />

Setup funkt.<br />

(förkortat namn)<br />

Inkopplad<br />

utrustn.<br />

(namn)<br />

Inkopplad till terminal<br />

(använd en av tillgänglig från listan)<br />

FLUX1 Ej inkopplad – – – –<br />

RC25 Inkopplad till Robnet ROBNET*<br />

Kopplingsbox: HS+, HS–<br />

Tillägna hårdvaru<br />

port till setup funkt.<br />

(* = fabriksinst.)<br />

J50-HS<br />

J50, Power PCB NMEA I/P RX2+,RX2– J50-2<br />

NI300X, NMEA port #1<br />

NI300X, NMEA port #2<br />

NI300X, NMEA port #3<br />

NI300X, NMEA port #4<br />

CI300X, Analog terminal<br />

NI300-1<br />

NI300-2<br />

NI300-3<br />

NI300-4<br />

CI300X<br />

FLUX2 Ej inkopplad – – – – *<br />

RC25 Inkopplad till Robnet ROBNET<br />

Kopplingsbox: HS+, HS–<br />

J50-HS<br />

J50, Power PCB NMEA I/P RX2+,RX2– J50-2<br />

NI300X, NMEA port #1<br />

NI300X, NMEA port #2<br />

NI300X, NMEA port #3<br />

NI300X, NMEA port #4<br />

CI300X, Analog terminal<br />

NI300-1<br />

NI300-2<br />

NI300-3<br />

NI300-4<br />

CI300X<br />

VIND Ej inkopplad – – – – *<br />

J50, Main PCB NMEA I/P RX1+,RX1– J50-1<br />

J50, Power PCB NMEA I/P RX2+,RX2– J50-2<br />

NI300X, NMEA port #1<br />

NI300X, NMEA port #2<br />

NI300X, NMEA port #3<br />

NI300X, NMEA port #4<br />

NI300-1<br />

NI300-2<br />

NI300-3<br />

NI300-4<br />

DJUP Ej inkopplad – – – – *<br />

J50, Main PCB NMEA I/P RX1+,RX1– J50-1<br />

J50, Power PCB NMEA I/P RX2+,RX2– J50-2<br />

NI300X, NMEA port #1<br />

NI300X, NMEA port #2<br />

NI300X, NMEA port #3<br />

NI300X, NMEA port #4<br />

NI300-1<br />

NI300-2<br />

NI300-3<br />

NI300-4<br />

LOG Ej inkopplad – – – – *<br />

J50, Main PCB NMEA I/P RX1+,RX1– J50-1<br />

J50, Power PCB NMEA I/P RX2+,RX2– J50-2<br />

NI300X, NMEA port #1<br />

NI300X, NMEA port #2<br />

NI300X, NMEA port #3<br />

NI300X, NMEA port #4<br />

GI51 Puls log terminal<br />

J50 = Alla modeller av kopplingsboxar<br />

NI300-1<br />

NI300-2<br />

NI300-3<br />

NI300-4<br />

GI-LOG<br />

20222642 / B 59