10.07.2015 Views

ENDA ETC1311 DIGITAL THERMOSTAT - SURAN Industrieelektronik

ENDA ETC1311 DIGITAL THERMOSTAT - SURAN Industrieelektronik

ENDA ETC1311 DIGITAL THERMOSTAT - SURAN Industrieelektronik

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

HEATING OUTLEDDisplayed process value in the run mode, parameter name or value in programming mode.1000IfSETOUT<strong>ENDA</strong>When pressed or key, temperature set value flashes and by using and keys the value can be adjusted.If no key is pressed for 3 seconds run mode is returned.Switch hysteresisfor the setpoint.Run modeProcessValue 200 199 200key is pressed and held for 3 seconds,programming mode is entered.ConHys°CPRG SET<strong>ETC1311</strong>Used for selecting menu and increasing setpoint value of the parameters in the programming mode and forincreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.Used for selecting parameters and decreasing the setpoint value in the programming mode and for decreasingthe setpoint value in the run mode. When held down for a few seconds, the change rate accelerates.Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode.SETWhile holding key, setpoint value of the selected parameter appears and by using and keys the value can be adjusted.Programming ModeSeCCodAccess code for menu of security.Enter311then press key.If no key is pressedfor 3 secondsIf key is pressed,run mode is entered.SETConHysUplLoLEonEctoFSSECAcoASEPARAMETER TABLEMenu of Configuration parametersSwitch hysteresis for the setpoint. (When temperaturefalls to SET-HYS, output relay becomes active.)The upper limit of the setpoint.The lower limit of the setpoint.In the case of error, on time rate of the relay output.In the case of error, period of the relay output.Offsetvalue (can be adjusted from -99...+99C° to a desired value)Menu of Parameter securitySecurity parameter for menu of configuration.Non=Menu is invisible.Pye=Parameters of menu are changeable.Pno=Parameters of menu are only visible.Security parameter for temperature set value.Pye=Set value is changeable.Pno=Set value is only visible.MIN MAX UNIT DEF.SET1 20 °C 1LoL 600°C 6000 UPL °C 00 100 % Ect 010 250 sec 30UplThe upper limitof the setpoint.AcoSecurity parameter for menu of configuration.Non= Menu is invisible.Pye= Parameters of menu are changeable.Pno= Parameters of menu are only visible.LolThe lower limitof the setpoint.AseSecurity parameter for temperature set value.Pye= Set value is changeable.Pno= Set value is only visible.Error Messages---Means, temperature value is higher than the scale.EonIn the case of error,on time rate ofthe relay output.___Means, temperature value is lower than the scale.PfaMeans, temperature sensor is broken or over temperature.EctIn the case of error,period ofthe relay output.oFSOffsetvalue (can be adjustedfrom -99...+99C°)2./2 <strong>ETC1311</strong>-E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!