Instrucciones de montaje - Dometic
Instrucciones de montaje - Dometic
Instrucciones de montaje - Dometic
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
_IA_CA1000.book Seite 34 Freitag, 30. Januar 2009 11:12 11<br />
Disposal<br />
<strong>Dometic</strong> CA1000<br />
8 Disposal<br />
➤ Place the packaging material in the appropriate recycling waste bins<br />
wherever possible.<br />
9 Troubleshooting<br />
Possible malfunction Cause Remedies<br />
Error message F02:<br />
The system does not<br />
switch on and the display<br />
shows an error message.<br />
Error message F04:<br />
The con<strong>de</strong>nsation water<br />
that has formed is not<br />
being discharged, and<br />
an error message<br />
appears in the display.<br />
The temperature sensor is not correctly<br />
connected.<br />
– The pump is clogged or <strong>de</strong>fective.<br />
– The con<strong>de</strong>nsation water hose is<br />
clogged.<br />
– The float switch is <strong>de</strong>fective or<br />
jammed.<br />
➤ Switch off the system<br />
➤ Switch it on again after 10 minutes<br />
➤ If the fault occurs again, contact<br />
an authorised workshop.<br />
➤ Contact an authorised workshop.<br />
34