_IA_CA1000.book Seite 34 Freitag, 30. Januar 2009 11:12 11<br />

Disposal<br />

<strong>Dometic</strong> CA1000<br />

8 Disposal<br />

➤ Place the packaging material in the appropriate recycling waste bins<br />

wherever possible.<br />

9 Troubleshooting<br />

Possible malfunction Cause Remedies<br />

Error message F02:<br />

The system does not<br />

switch on and the display<br />

shows an error message.<br />

Error message F04:<br />

The con<strong>de</strong>nsation water<br />

that has formed is not<br />

being discharged, and<br />

an error message<br />

appears in the display.<br />

The temperature sensor is not correctly<br />

connected.<br />

– The pump is clogged or <strong>de</strong>fective.<br />

– The con<strong>de</strong>nsation water hose is<br />

clogged.<br />

– The float switch is <strong>de</strong>fective or<br />

jammed.<br />

➤ Switch off the system<br />

➤ Switch it on again after 10 minutes<br />

➤ If the fault occurs again, contact<br />

an authorised workshop.<br />

➤ Contact an authorised workshop.<br />