7.1 Initial operation<br />
The chapter “Safety instructions” must be<br />
heeded!<br />
The switch unit is easy to use and does not require<br />
any technical knowledge. However, you<br />
are required to read the installation, operating<br />
and maintenance instructions through carefully<br />
prior to use and heed all the instructions.<br />
Once the unit has been mounted and all the electrical<br />
and mechanical components have<br />
been connected up correctly, it can be put into<br />
operation.<br />
To do this, insert the mains plug into a safety<br />
socket. The unit is in normal mode. The green<br />
LED lights up to show operation.<br />
7. Operation<br />
7.2 Normal mode:<br />
If the rainwater cistern is full enough, with the<br />
water level above level 1, the system runs in<br />
rainwater mode. When required, service water<br />
is pumped from the cistern to the consumer.<br />
If the water level drops to below level 1, drinking<br />
water feeding is activated automatically.<br />
The orange LED lights up to show drinking<br />
water feeding.<br />
This state remains until the water level in the<br />
cistern has risen to above level 2. The orange<br />
LED for drinking water feeding goes out.<br />
34<br />
7.3 Manual drinking water feeding<br />
The button “drinking water feeding” can be<br />
pressed to switch drinking water feeding on<br />
and off manually. When switched on, the orange<br />
LED flashes, showing drinking water feeding.<br />
Important note!<br />
Manual drinking water feeding remains active<br />
until it is switched off by the button<br />
“drinking water feeding” being pressed<br />
again.