Bedienungsanleitung RolloTube I-line Sun Funk - Rademacher
Bedienungsanleitung RolloTube I-line Sun Funk - Rademacher
Bedienungsanleitung RolloTube I-line Sun Funk - Rademacher
Erfolgreiche ePaper selbst erstellen
Machen Sie aus Ihren PDF Publikationen ein blätterbares Flipbook mit unserer einzigartigen Google optimierten e-Paper Software.
46<br />
i<br />
What to do if... ?<br />
...the motor fails to start?<br />
Possible cause:<br />
◆ Mains power not available.<br />
◆ The thermal protection system has triggered.<br />
Solution:<br />
◆ Check the power with a meter to ensure that the supply voltage (230 V / 50 Hz)<br />
is available and check the wiring.<br />
◆ Wait approx. 20 minutes until the motor has cooled down.<br />
...The tubular motor stops after a short period of time during the<br />
configuration and test procedures?<br />
Possible cause:<br />
◆ The adapter (8) may have slipped off of the limit ring (14) on the drive head (6).<br />
Solution:<br />
◆ Check that the adapter (8) sits flush with the drive head (6) and is fully inserted<br />
into the awning shaft (11).<br />
Slide the adapter (8) back so that it is flush with the drive head (6) and slide the<br />
tubular motor into the awning shaft (11) until the adapter (8) is flush with the awning<br />
shaft (11), see Fig. 2 and 4. Re-adjust the end points if necessary, see<br />
page 43.<br />
EN<br />
...The tubular motor stops between the two end points during normal<br />
operation?<br />
Possible cause:<br />
◆ The thermal protection system has triggered.<br />
Solution:<br />
◆ Wait approx. 20 minutes until the motor has cooled down.<br />
The tubular motor stops whilst extending the awning?<br />
Possible cause:<br />
◆ The motor must push the awning fabric out, because the shaft is not running smoothly<br />
or it is corroded.<br />
Solution:<br />
◆ Mount the catch (10) without the freewheel mechanism (see page ).