Identification and Approval Inspection Record - Layher
Identification and Approval Inspection Record - Layher
Identification and Approval Inspection Record - Layher
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Identification</strong> <strong>and</strong> <strong>Approval</strong> <strong>Inspection</strong> <strong>Record</strong><br />
of mobile working platforms (rolling towers) as per DIN EN 1004<br />
as per Sections 10 <strong>and</strong> 11 of the German Ordinance on Industrial Safety <strong>and</strong> Health (BetrSichV)<br />
Scaffolding erector:<br />
Telephone number:<br />
Place of erection:<br />
Tower No.:<br />
Scaffolding group: � 2 (150 kg/m²) � 3 (200 kg/m²)<br />
The sum of the live loads of all scaffolding levels positioned one above the other inside one scaffolding bay<br />
must not exceed the above value.<br />
Access type:<br />
outside buildings: ________________ m<br />
inside buildings: ________________ m<br />
Restrictions on use applying to the user:<br />
Inspected <strong>and</strong> approved<br />
Qualified person of scaffolding erector:<br />
Date, signature<br />
Qualified person during assembly:<br />
Assembly period:<br />
Qualified person for inspection:<br />
<strong>Inspection</strong> period:<br />
Client:<br />
Telephone number:<br />
� A Stairway � B Step Ladder � C Angled Ladder � D Vertical Ladder<br />
Maximum permissible platform height as per instructions for assembly <strong>and</strong> use.<br />
Unauthorized changes to the scaffolding are prohibited unless the scaffolding erector<br />
has been consulted beforeh<strong>and</strong>! The castors must be locked during work on the scaffolding.<br />
The instructions for assembly <strong>and</strong> use must be carefully complied with!<br />
Wilhelm <strong>Layher</strong> GmbH & Co. KG<br />
Scaffolding Gr<strong>and</strong>st<strong>and</strong>s Ladders<br />
Ochsenbacher Strasse 56<br />
D-74363 Gueglingen-Eibensbach<br />
Qualified person of user:<br />
Date, signature<br />
Tower No.: ____________________________<br />
Notes <strong>and</strong> comments:<br />
Inspected <strong>and</strong> approved<br />
Qualified person of scaffolding erector:<br />
Date, signature<br />
Qualified person of user:<br />
Date, signature<br />
Yes No<br />
Scaffolding components no visible damaged � �<br />
Castors load bearing capacity suitable � �<br />
provided with locking brake / � �<br />
secured by locking screw against breaking loose � �<br />
Ladder Frames paired ladders with double bracing � �<br />
horizontal bracing in the basic structure � �<br />
st<strong>and</strong>ard joints secured (spring clip) � �<br />
Decks decks / hatches in suitable number / spacing � �<br />
Accesses stairway, step ladder, angled ladder or vertical � �<br />
ladder provided<br />
Side protection 3-part side protection fitted at all working levels � �<br />
Ballast ballasting as per instructions for assembly <strong>and</strong> use � �<br />
Widening suitable for height � �<br />
Special structures According to Instructions for Assembly <strong>and</strong> Use / Static � �
Directions for use:<br />
• Level the tower using the adjusting spindles.<br />
• Access to the working platform is permitted only on the inside of the scaffolding.<br />
• Working on two or more working levels at the same time is not permitted.<br />
• The mobile working platform must not be tilted by horizontal loads, such as by pressure<br />
applied to the side protection during demolition work.<br />
• Assembly <strong>and</strong> movement are only permitted on sufficiently firm ground, <strong>and</strong> only in a<br />
longitudinal or diagonal direction. Avoid any impacts.<br />
• No personnel <strong>and</strong>/or loose objects may be on the tower while it is being moved.<br />
• After movement, lock the castors by pressing down the brake lever.<br />
• The scaffolding structures must not be subjected to any aggressive fluids or gases.<br />
• Mobile working platforms must not be connected by bridges to one another or to buildings.<br />
• When the mobile working platform is used outdoors or in open buildings, it must be moved to<br />
a wind-protected area when wind strengths exceed 6 on the Beaufort scale or at the end of a<br />
shift, or secured against toppling over by other suitable measures.<br />
• Decks can also be moved up or down by one rung to reach a different working height (ensure<br />
continued side protection).<br />
• The access hatches must be kept shut whenever they are not in use.<br />
• Climbing over from rolling towers is prohibited.<br />
• Jumping onto decked surfaces is prohibited.<br />
• It is prohibited to increase the height of the deck using ladders, boxes or other objects.<br />
• Mobile working platforms are not designed to be lifted or suspended.<br />
Wilhelm <strong>Layher</strong> GmbH & Co. KG<br />
Scaffolding Gr<strong>and</strong>st<strong>and</strong>s Ladders<br />
Ochsenbacher Strasse 56<br />
D-74363 Gueglingen-Eibensbach<br />
Unauthorized changes to the scaffolding are prohibited unless the scaffolding<br />
erector has been consulted beforeh<strong>and</strong>! The castors must be locked during<br />
work on the scaffolding.<br />
The instructions for assembly <strong>and</strong> use must be carefully complied with!