<strong>FPD</strong>-<strong>7024</strong> | Operation and Installation Guide | 4.0 Programming<br />
4.6 Shortcuts<br />
You can use shortcuts to reduce repetition and<br />
provide speedy instructions for programming the<br />
control panel.<br />
The first level in the system is the Main Menu. For<br />
all system programming, is your Main<br />
Menu choice. Therefore, the first number in the<br />
shortcut is “0”.<br />
The second level in your system provides eight<br />
options: PROG TIME, SECURITY, PROG<br />
SYSTEM, PROG INPUTS, PROG OUTPUTS,<br />
PROG ACCOUNTS, PROG FORMATS, and<br />
HISTORY DEFAULTS. When the D7039 MUX<br />
Expander is installed, a ninth option appears:<br />
PROGRAM MUX. The second number in the<br />
shortcut enters the Level 2 option and allows<br />
access to Level 3.<br />
38<br />
Figure 12: Example of a Programming Shortcut<br />
Shortcut = 0 1 2<br />
Use “0” to select PROG<br />
from the Main Menu which<br />
scrolls at the System Normal<br />
display (Refer to Section 5 .3<br />
Prog System on page 41 for<br />
more details).<br />
LEVEL 1<br />
(MAIN MENU)<br />
PROG/0<br />
First number<br />
in shortcut<br />
LEVEL 2 LEVEL 3 LEVEL 4<br />
1- PROG TIME<br />
Second number<br />
in shortcut<br />
Use “1” to select<br />
PROG TIME from<br />
Sub-Level 2.<br />
1- SYSTEM<br />
2- AUTO TEST<br />
Level 3 provides the third set of options that branch<br />
from Level 2 (Figure 12). The third number in the<br />
shortcut represents the option chosen in Level 3.<br />
Figure 12 is an example of the shortcut to TEST<br />
FREQ and TEST TIME. The sample of the<br />
Program Menu Tree shows that to get to TEST<br />
TIME and TEST FREQ, you must go to PROG/0 in<br />
Level 1, PROG TIME in Level 2, and AUTO TEST<br />
in Level 3. The shortcut is simply a list of the keys<br />
you press to get to the fourth level option. Once<br />
you enter the shortcut, follow the procedural<br />
description that appears on the screen of the<br />
specific function you are programming.<br />
Use “2” to select AUTO TEST<br />
from Sub-Level 3. Follow the procedural<br />
description that appears on the screen.<br />
The particular short cut in this example<br />
is for Section 5.1.2 Automatic Test<br />
on page 38.<br />
TEST FREQ<br />
TEST TIME<br />
Third number<br />
in shortcut<br />
Bosch <strong>Security</strong> <strong>Systems</strong>, Inc. | 1/10 | F01U008458-03