24.02.2013 Views

Acoustical Ceiling Systems 2011 2012 - USG Middle East

Acoustical Ceiling Systems 2011 2012 - USG Middle East

Acoustical Ceiling Systems 2011 2012 - USG Middle East

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

18<br />

Light reflectance selector<br />

The Light Reflectance selector identifies <strong>USG</strong> ceiling panels that<br />

efficiently reflect light within a space to enhance indirect lighting,<br />

reduce energy consumption and create a warm, luminous aesthetic.<br />

Measured per ASTM E14771, LR value represents the percentage of<br />

light reflected from the surface of a material. The industry average for<br />

panels is LR .70 to .80, and values above LR .85 are considered high.<br />

<strong>USG</strong> offers numerous panels with LR values at these levels, including<br />

SONATA, MARS CLIMAPLUS, OLYMPIA II and OLYMPIA MICRO<br />

PERFORATED, with LR .89.<br />

• Choosing high-LR ceiling panels is a great way to improve the utility and comfort<br />

of the spaces you design and make your projects bright and inviting. Indirect lighting,<br />

combined with high-LR panels, can eliminate dark, shadowy areas and too-bright hot<br />

spots, improving the look and feel of a space and minimizing eyestrain (a cause of<br />

employee fatigue).<br />

High-LR ceilings can also help conserve energy and cut operating costs by achieving<br />

the same light levels with fewer fixtures and lower-wattage bulbs. Fewer fixtures also<br />

mean less repairs and lower maintenance costs.<br />

Architects typically select high-LR ceiling for spaces that make extensive use of<br />

indirect lighting. However, these panels can enhance almost any lighting scheme and<br />

so can be an effective choice for many design applications.<br />

Many <strong>USG</strong> panels with high LR values also feature high NRC and CAC ratings so you<br />

dont have to compromise acoustics for aesthetics. Panels are available in a range of<br />

textures including smooth and very fine, many include CLIMAPLUS performance, and<br />

several are cast products, which provide a higher level of durability to resisit and hide<br />

scrapes and scratches.<br />

Sonata .89 Fine 38<br />

Clean Room ClimaPlus .79 Smooth / Fine 28<br />

Mars ClimaPlus .89 Fine 32<br />

Radar Ceramic ClimaPlus .82 Medium 34<br />

Sonatone White - Sparta .84 Fine 50<br />

Glacier .70 Heavy 30<br />

Olympia II Micro Perforated .89 Fine 44<br />

Pedestals I .85 Smooth 70<br />

Sandrift ClimaPlus .83 Medium 36<br />

Comet Line .75 Medium 66<br />

Chessboard .75 Medium 64<br />

Cross Fissured .82 Medium 52<br />

Designer Squares .88 Medium 68<br />

Favia .85 Medium 54<br />

Favia Acoustic .75 Medium 56<br />

Olympia II .89 Fine 42<br />

Omni .85 Medium 62<br />

Perforated .84 Fine 46<br />

Plain .85 Smooth 48<br />

Radar .85 Medium 58<br />

Rocktone .85 Medium 60<br />

Taiga Hygiene IITM <strong>Ceiling</strong> Panels LR1 Textures Page<br />

.85 Medium 40<br />

1. Standard Test Method for Luminous Reflectance Factor of <strong>Acoustical</strong> Materials by Use of<br />

Integrating-Sphere Reflectometers.<br />

Light Reflectance<br />

It is a measure of the percentage of light<br />

which is reflected off of a given panel surface.<br />

Typically, the whiter and smoother the panel,<br />

the higher the LR value.<br />

• Enhance Indirect Lighting<br />

• Reduce Energy Consumption<br />

• Create Warm Lumnous Aesthetics<br />

<strong>USG</strong> <strong>Ceiling</strong>s Provide<br />

LR (Light Reflectance)<br />

(70-90%)<br />

Product name Page Type<br />

Fire Reaction<br />

BS 476<br />

Part 6/7<br />

Fire Resistance BS-476 Humidity<br />

Resistance<br />

Steel Beam Timber Floor<br />

Maximum<br />

(pt.23) (pt.21) % RH/C/°F<br />

<strong>Acoustical</strong><br />

Performance<br />

NRC CAC Range<br />

LR1<br />

Sonata 38-39 CP Class 1,0 30 min 30 min 95/40/104 0.70 35-45 .89<br />

Clean Room ClimaPlus 28-29 FC+CP Class 1,0 120 min 120 min 90/40/104 0.15-0.55 35 .79<br />

Mars ClimaPlus 32-33 CP Class 1,0 30 min 30 min 95/40/104 0.70 35-45 .89<br />

Radar Ceramic ClimaPlus 34-35 FC Class 1,0 120 min 120 min 100/40/104 0.55 40 .82<br />

Sonatone White - Sparta 50-51 R Class 1,0 30 min 30 min 95/32/90 0.20 35 .84<br />

Glacier 30-31 R+FC Class 1,0 120 min 120 min 70/29/84 0.65 35-45 .70<br />

Olympia II Micro Perforated 42-45 R+CP Class 1,0 30 min 30 min 90/32/90 0.60 35-39 .89<br />

Pedestals I 70-71 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .85<br />

Sandrift ClimaPlus 36-37 FC+CP Class 1,0 120 min 120 min 70/29/84 0.70 38-48 .83<br />

Comet Line 66-67 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .75<br />

Chessboard 64-65 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .75<br />

Cross Fissured 52-53 R+FC+CP Class 1,0 30/120 min 30/120 min 90/32/90 0.45-0.60 35-39 .82<br />

Designer Squares 68-69 R Class 1,0 30 min 30 min 90/32/90 0.15-0.60 35-39 .88<br />

Favia 54-55 R Class 1,0 30 min 30 min 90/32/90 0.40 35-39 .85<br />

Favia Acoustic 56-57 R+CP Class 1,0 30 min 30 min 90/32/90 0.50-0.60 35-39 .75<br />

Olympia II 42-43 R+FC+CP Class 1,0 30/120 min 30/120 min 90/32/90 0.15 35-39 .89<br />

Omni 62-63 R+FC+CP Class 1,0 30/120 min 30/120 min 90/32/90 0.50-0.60 35-39 .85<br />

Perforated 46-47 R Class 1,0 30 min 30 min 90/32/90 0.45-0.60 35-39 .84<br />

Plain 48-48 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .85<br />

Radar 58-59 R+FC+CP Class 1,0 30/120 min 30/120 min 90/32/90 0.50-0.60 35-39 .85<br />

Rocktone 60-61 R Class 1,0 30 min 30 min 90/32/90 0.50 35-39 .85<br />

Taiga Hygiene IITM 40-41 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .85<br />

• Radar Ceramic ClimaPlus also certified to BS 476 pt. 4 - non-combustible. ** Summary table<br />

19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!