18<br />
Light reflectance selector<br />
The Light Reflectance selector identifies <strong>USG</strong> ceiling panels that<br />
efficiently reflect light within a space to enhance indirect lighting,<br />
reduce energy consumption and create a warm, luminous aesthetic.<br />
Measured per ASTM E14771, LR value represents the percentage of<br />
light reflected from the surface of a material. The industry average for<br />
panels is LR .70 to .80, and values above LR .85 are considered high.<br />
<strong>USG</strong> offers numerous panels with LR values at these levels, including<br />
SONATA, MARS CLIMAPLUS, OLYMPIA II and OLYMPIA MICRO<br />
PERFORATED, with LR .89.<br />
• Choosing high-LR ceiling panels is a great way to improve the utility and comfort<br />
of the spaces you design and make your projects bright and inviting. Indirect lighting,<br />
combined with high-LR panels, can eliminate dark, shadowy areas and too-bright hot<br />
spots, improving the look and feel of a space and minimizing eyestrain (a cause of<br />
employee fatigue).<br />
High-LR ceilings can also help conserve energy and cut operating costs by achieving<br />
the same light levels with fewer fixtures and lower-wattage bulbs. Fewer fixtures also<br />
mean less repairs and lower maintenance costs.<br />
Architects typically select high-LR ceiling for spaces that make extensive use of<br />
indirect lighting. However, these panels can enhance almost any lighting scheme and<br />
so can be an effective choice for many design applications.<br />
Many <strong>USG</strong> panels with high LR values also feature high NRC and CAC ratings so you<br />
dont have to compromise acoustics for aesthetics. Panels are available in a range of<br />
textures including smooth and very fine, many include CLIMAPLUS performance, and<br />
several are cast products, which provide a higher level of durability to resisit and hide<br />
scrapes and scratches.<br />
Sonata .89 Fine 38<br />
Clean Room ClimaPlus .79 Smooth / Fine 28<br />
Mars ClimaPlus .89 Fine 32<br />
Radar Ceramic ClimaPlus .82 Medium 34<br />
Sonatone White - Sparta .84 Fine 50<br />
Glacier .70 Heavy 30<br />
Olympia II Micro Perforated .89 Fine 44<br />
Pedestals I .85 Smooth 70<br />
Sandrift ClimaPlus .83 Medium 36<br />
Comet Line .75 Medium 66<br />
Chessboard .75 Medium 64<br />
Cross Fissured .82 Medium 52<br />
Designer Squares .88 Medium 68<br />
Favia .85 Medium 54<br />
Favia Acoustic .75 Medium 56<br />
Olympia II .89 Fine 42<br />
Omni .85 Medium 62<br />
Perforated .84 Fine 46<br />
Plain .85 Smooth 48<br />
Radar .85 Medium 58<br />
Rocktone .85 Medium 60<br />
Taiga Hygiene IITM <strong>Ceiling</strong> Panels LR1 Textures Page<br />
.85 Medium 40<br />
1. Standard Test Method for Luminous Reflectance Factor of <strong>Acoustical</strong> Materials by Use of<br />
Integrating-Sphere Reflectometers.<br />
Light Reflectance<br />
It is a measure of the percentage of light<br />
which is reflected off of a given panel surface.<br />
Typically, the whiter and smoother the panel,<br />
the higher the LR value.<br />
• Enhance Indirect Lighting<br />
• Reduce Energy Consumption<br />
• Create Warm Lumnous Aesthetics<br />
<strong>USG</strong> <strong>Ceiling</strong>s Provide<br />
LR (Light Reflectance)<br />
(70-90%)<br />
Product name Page Type<br />
Fire Reaction<br />
BS 476<br />
Part 6/7<br />
Fire Resistance BS-476 Humidity<br />
Resistance<br />
Steel Beam Timber Floor<br />
Maximum<br />
(pt.23) (pt.21) % RH/C/°F<br />
<strong>Acoustical</strong><br />
Performance<br />
NRC CAC Range<br />
LR1<br />
Sonata 38-39 CP Class 1,0 30 min 30 min 95/40/104 0.70 35-45 .89<br />
Clean Room ClimaPlus 28-29 FC+CP Class 1,0 120 min 120 min 90/40/104 0.15-0.55 35 .79<br />
Mars ClimaPlus 32-33 CP Class 1,0 30 min 30 min 95/40/104 0.70 35-45 .89<br />
Radar Ceramic ClimaPlus 34-35 FC Class 1,0 120 min 120 min 100/40/104 0.55 40 .82<br />
Sonatone White - Sparta 50-51 R Class 1,0 30 min 30 min 95/32/90 0.20 35 .84<br />
Glacier 30-31 R+FC Class 1,0 120 min 120 min 70/29/84 0.65 35-45 .70<br />
Olympia II Micro Perforated 42-45 R+CP Class 1,0 30 min 30 min 90/32/90 0.60 35-39 .89<br />
Pedestals I 70-71 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .85<br />
Sandrift ClimaPlus 36-37 FC+CP Class 1,0 120 min 120 min 70/29/84 0.70 38-48 .83<br />
Comet Line 66-67 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .75<br />
Chessboard 64-65 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .75<br />
Cross Fissured 52-53 R+FC+CP Class 1,0 30/120 min 30/120 min 90/32/90 0.45-0.60 35-39 .82<br />
Designer Squares 68-69 R Class 1,0 30 min 30 min 90/32/90 0.15-0.60 35-39 .88<br />
Favia 54-55 R Class 1,0 30 min 30 min 90/32/90 0.40 35-39 .85<br />
Favia Acoustic 56-57 R+CP Class 1,0 30 min 30 min 90/32/90 0.50-0.60 35-39 .75<br />
Olympia II 42-43 R+FC+CP Class 1,0 30/120 min 30/120 min 90/32/90 0.15 35-39 .89<br />
Omni 62-63 R+FC+CP Class 1,0 30/120 min 30/120 min 90/32/90 0.50-0.60 35-39 .85<br />
Perforated 46-47 R Class 1,0 30 min 30 min 90/32/90 0.45-0.60 35-39 .84<br />
Plain 48-48 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .85<br />
Radar 58-59 R+FC+CP Class 1,0 30/120 min 30/120 min 90/32/90 0.50-0.60 35-39 .85<br />
Rocktone 60-61 R Class 1,0 30 min 30 min 90/32/90 0.50 35-39 .85<br />
Taiga Hygiene IITM 40-41 R Class 1,0 30 min 30 min 90/32/90 0.15 35-39 .85<br />
• Radar Ceramic ClimaPlus also certified to BS 476 pt. 4 - non-combustible. ** Summary table<br />