Type LLV050060/EMV 5060<br />

Accessories<br />

plug<br />

bellows<br />

We reserve the right to make changes<br />

to the product design.<br />

Please note ordering data!<br />

Example of order<br />

LLV050060/EMV 5060<br />

24 VDC, 100% duty cycle<br />

de-energised locking<br />

Technical specification<br />

Insulation class F to<br />

DIN VDE 0580 (July 2000)<br />

100% duty cycle<br />

Class of protection to IEC 60529: IP 64<br />

Parameters specific to product<br />

starting force/locking bolt FS = 7 N<br />

holding force/locking bolt FH = 35 N<br />

restoring force/locking bolt FR = 20 N<br />

response time t1 = 120 ms<br />

release time t2 = 100 ms<br />

radial force/stationary 3000 N<br />

Circuit diagram and pin assignment at plug<br />

(solenoid de-energised)<br />

LLV050060 / EMV 5060<br />

Locking solenoid<br />

type LLV050060/EMV 5060<br />

This is an electromagnetic locking unit specially designed<br />

for use in all kinds of safety devices on machines and<br />

automatic systems. During its development special<br />

attention was given to ensuring a compact design,<br />

universal fixing options and an integral acknowledgement<br />

signal for the locking function. These devices comply<br />

fully with the requirements of Germany’s Accident<br />

Prevention Regulations – and with a large factor of<br />

safety. The solenoid plunger and locking bolt are<br />

guided separately in highly wear-resistant, maintenancefree<br />

bearings. The integral microswitches signal the<br />

respective position of the locking bolt approx.<br />

0.5-1 mm after it leaves the initial position or before<br />

it reaches the end position. The return movement of<br />

the locking bolt into the locked position is achieved by<br />

means of an integral spring.<br />

In order to achieve a quick and reliable electrical<br />

connection, a common integral DIN 43651 plug is used<br />

for the linear solenoid and the acknowledgement<br />

signal.<br />

When operating the locking units with voltages<br />

exceeding 48 VDC, the linear solenoid is connected via<br />

an additional device connector (to DIN EN 175301-803<br />

– DIN 43650) mounted on the solenoid housing.<br />

Size<br />

LLV050060<br />

Function<br />

(de-energised)<br />

unlocked<br />

6 www.kendrionmt.com<br />

locking solenoids<br />

Fixings<br />

Stroke<br />

[mm]<br />

10<br />

Power<br />

[Watt]<br />

18.5<br />

The magnetic forces given are reached at operating<br />

temperature and 90% of the rated voltage according<br />

to DIN VDE 0580 (July 2000), and are valid for a<br />

24 VDC supply voltage. When operating at 100% rated<br />

voltage, the magnetic forces increase by approx. 20%.<br />

Different supply voltages may lead to magnetic forces<br />

higher or lower than the specified values owing to the<br />

changing copper factor. The release times are based on<br />

switching on the DC side. With a rectifier in series and<br />

switching on the AC side, the release times are 2 to 3<br />

times higher.<br />

Device connectors are not included in the scope of<br />

supply and must be ordered separately.<br />

Surface finish: solenoid galvanised<br />

Locking bolt housing: aluminium<br />

Special versions on request.<br />

Locking bolt<br />

Ø [mm]<br />

14<br />

deep<br />

Sensor<br />

H A<br />

x x<br />

H E<br />

Weight<br />

[kg]<br />

1.4