LOCKING LINE catalogue - Kendrion Binder
LOCKING LINE catalogue - Kendrion Binder
LOCKING LINE catalogue - Kendrion Binder
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Type LLV050060/EMV 5060<br />
Accessories<br />
plug<br />
bellows<br />
We reserve the right to make changes<br />
to the product design.<br />
Please note ordering data!<br />
Example of order<br />
LLV050060/EMV 5060<br />
24 VDC, 100% duty cycle<br />
de-energised locking<br />
Technical specification<br />
Insulation class F to<br />
DIN VDE 0580 (July 2000)<br />
100% duty cycle<br />
Class of protection to IEC 60529: IP 64<br />
Parameters specific to product<br />
starting force/locking bolt FS = 7 N<br />
holding force/locking bolt FH = 35 N<br />
restoring force/locking bolt FR = 20 N<br />
response time t1 = 120 ms<br />
release time t2 = 100 ms<br />
radial force/stationary 3000 N<br />
Circuit diagram and pin assignment at plug<br />
(solenoid de-energised)<br />
LLV050060 / EMV 5060<br />
Locking solenoid<br />
type LLV050060/EMV 5060<br />
This is an electromagnetic locking unit specially designed<br />
for use in all kinds of safety devices on machines and<br />
automatic systems. During its development special<br />
attention was given to ensuring a compact design,<br />
universal fixing options and an integral acknowledgement<br />
signal for the locking function. These devices comply<br />
fully with the requirements of Germany’s Accident<br />
Prevention Regulations – and with a large factor of<br />
safety. The solenoid plunger and locking bolt are<br />
guided separately in highly wear-resistant, maintenancefree<br />
bearings. The integral microswitches signal the<br />
respective position of the locking bolt approx.<br />
0.5-1 mm after it leaves the initial position or before<br />
it reaches the end position. The return movement of<br />
the locking bolt into the locked position is achieved by<br />
means of an integral spring.<br />
In order to achieve a quick and reliable electrical<br />
connection, a common integral DIN 43651 plug is used<br />
for the linear solenoid and the acknowledgement<br />
signal.<br />
When operating the locking units with voltages<br />
exceeding 48 VDC, the linear solenoid is connected via<br />
an additional device connector (to DIN EN 175301-803<br />
– DIN 43650) mounted on the solenoid housing.<br />
Size<br />
LLV050060<br />
Function<br />
(de-energised)<br />
unlocked<br />
6 www.kendrionmt.com<br />
locking solenoids<br />
Fixings<br />
Stroke<br />
[mm]<br />
10<br />
Power<br />
[Watt]<br />
18.5<br />
The magnetic forces given are reached at operating<br />
temperature and 90% of the rated voltage according<br />
to DIN VDE 0580 (July 2000), and are valid for a<br />
24 VDC supply voltage. When operating at 100% rated<br />
voltage, the magnetic forces increase by approx. 20%.<br />
Different supply voltages may lead to magnetic forces<br />
higher or lower than the specified values owing to the<br />
changing copper factor. The release times are based on<br />
switching on the DC side. With a rectifier in series and<br />
switching on the AC side, the release times are 2 to 3<br />
times higher.<br />
Device connectors are not included in the scope of<br />
supply and must be ordered separately.<br />
Surface finish: solenoid galvanised<br />
Locking bolt housing: aluminium<br />
Special versions on request.<br />
Locking bolt<br />
Ø [mm]<br />
14<br />
deep<br />
Sensor<br />
H A<br />
x x<br />
H E<br />
Weight<br />
[kg]<br />
1.4