Laboratory Grade Instruments<br />

Model 4028 Power Sensor<br />

BIRD ® Model 4028<br />

High Power, Precision Power Sensors for Precision Process<br />

Applications<br />

A<strong>ch</strong>ieves tighter, more consistent RF power measurements<br />

for improved yields.<br />

• ± 2% at calibration frequencies and power levels.<br />

± 4% at other frequencies and power levels. Add 2% to<br />

uncertainty outside 25 ± 10 °C.<br />

• Direct, plug-in operation with the industry standard<br />

Bird ® Model 4421 RF Power Meter.<br />

• Multiple sensors provide for measurement over a 250 kHz to<br />

30 MHz frequency range<br />

• Capable of power measurements up to 50kW.<br />

With the expanding surface areas in the LCD and Solar panel industry, higher<br />

power levels are necessary for the industries processes. The Bird 4028 series<br />

sensor is designed to meet the growing RF power measurement <strong>ch</strong>allenge with<br />

accuracy, repeatability and versatility to meet current and future applications. Bird<br />

continues to innovate useful sensor te<strong>ch</strong>nology to meet these fast paced markets.<br />

4028 SERIES — Power Sensor<br />

Model Power Range Frequency<br />

4028A250K 1.0 kW-20 kW 250-400 kHz<br />

4028A400K 1.0 kW-20 kW 400-550 kHz<br />

4028A2M 1.0 kW-25 kW 1.5-2.5 MHz<br />

4028A3M 1.0 kW-25 kW 2.5-3.5 MHz<br />

4028A4M 1.0 kW-25 kW 3.5-4.5 MHz<br />

4028A10M 1.0 kW-25 kW 10-15 MHz<br />

4028A25M 1.0 kW-25 kW 25-30 MHz<br />

4028B3M 1.0 kW-25 kW 2.5-4 MHz<br />

4028B10M 1.0 kW-25 kW 10-15 MHz<br />

4028C10M 500 W-50 kW 10-15 MHz<br />

POWER MEASUREMENT<br />

Accuracy ±2% (1�) at calibration frequencies and power levels;<br />

±4% at other frequencies and power levels. Add 2% to<br />

uncertainty outside 25 ± 10°C<br />

Calibration Power Level 250 and 400kHz units: 1.7kW<br />

VSWR Range 1.0 to 2.0 (40.00 to 9.5 dB return loss)<br />

Directivity 28 dB<br />

Insertion Loss < 0.05dB<br />

Uniformity 2% maximum unit to unit, at calibration frequency<br />

and power levels.<br />

Speed 2 readings per second.<br />

Maximum Power 4028AxxK: 20kW<br />

4028AxxM: 25kW<br />

4028B: 25kW<br />

4028C: 50kW<br />

CONNECTORS<br />

4028A Series Customer Specified<br />

4028B Series 1-5/8 EIA Flanged<br />

4028C Series 3-1/8 EIA Flanged<br />

Sensor Interface Lat<strong>ch</strong>-n-Lock<br />

POWER REQUIREMENTS<br />

External DC 12 VDC, supplied from Bird 4421 Power Meter<br />

15 Bird ® Te<strong>ch</strong>nologies Group 1-866-695-4569 www.bird-te<strong>ch</strong>nologies.com<br />

PHYSICAL SPECIFICATIONS<br />

Dimensions 4.7" L x 3.2" W x 4.0" H (4028A Series)<br />

6.8" L x 3.5" W x 4.8" H (4028B Series)<br />

8.0" L x 5.2" W x 6.4" H (4028C Series)<br />

Weight 3.3 lbs. (4028A Series)<br />

5.2 lbs. (4028B Series)<br />

7.3 lbs. (4028C Series))<br />

ENVIRONMENTAL SPECIFICATIONS<br />

Operating Temperature 0°C to 50°C (32°F to 122°F)<br />

(derate accuracy outside 25 ± 10°C)<br />

Storage Temperature -20°C to 70°C (-4°F to 158°F)<br />

Humidity 95% non-condensing<br />

Altitude 10,000 feet (3,000 m)<br />

<strong>General</strong> EMC Designed to carry CE mark (with immunity<br />

exception noted below)<br />

Emissions EN-55011, 1991, Class B<br />

Immunity EN-50082-1, 1995<br />

Safety EN-61010, 1993 in accordance with Council<br />

Directives 73/23/EEC and 93/68/EEC<br />