EQQA303E EQQA314E<br />

EQQA303E OPERATION OP IS NOT CONNECTED TO APPLICATION<br />

Explanation: The operation (operation number OP) has no predecessor or successor connections to the application.<br />

System action: The system waits for you to respond.<br />

User response: Enter or change an internal predecessor to establish a correct application link.<br />

EQQA304E OPERATION OP SPECIFIES WORK STATION OPWS, WHICH IS NOT FOUND<br />

Explanation: The operation (operation number OP) of this application specifies a workstation (workstation name<br />

OPWS), which was not found in the workstation description database.<br />

System action: The system waits for you to respond.<br />

User response: Enter an existing workstation name or use the Workstation Description dialog to define the<br />

workstation name.<br />

EQQA305E DEPENDENCIES INCLUDING OPERATION OP FORM A LOOP<br />

Explanation: A loop was detected in the operation (operation number OP) dependency network which must be<br />

corrected. For example, operation 10 has operation 5 as its predecessor, <strong>and</strong> operation 5 has operation 10 as its<br />

predecessor.<br />

System action: The system waits for you to respond.<br />

User response: Correct the found loop with these internal predecessors.<br />

EQQA306E VALID-FROM DATE LATER THAN VALID-TO DATE<br />

Explanation: Data entry error; see “Data Entry Errors” on page 2.<br />

When modifying an application, the valid-from date cannot be changed to a date later than the valid-to date.<br />

EQQA307E OPERATION INPUT ARRIVAL TIME MUST BE SPECIFIED FOR A TIME JOB<br />

Explanation: Data entry error; see “Data Entry Errors” on page 2.<br />

If the time-dependent job option is specified as YES, an operation input arrival time must be specified.<br />

EQQA308E JOB SETUP OPERATION OP MUST HAVE A CPU SUCCESSOR<br />

Explanation: The job setup operation (operation number OP) must have a CPU successor operation.<br />

System action: The system waits for you to respond.<br />

User response: Enter the job setup operation number as a CPU predecessor number.<br />

EQQA309E PRINT OPERATION OP MUST HAVE A CPU PREDECESSOR<br />

Explanation: The print operation (operation number OP) must have a CPU predecessor operation.<br />

System action: The system waits for you to respond.<br />

User response: Enter a CPU operation number as the predecessor number.<br />

EQQA310E FIELD FORMAT SPECIFIED AS DBCS BUT INPUT NOT BRACKETED DBCS<br />

Explanation: Data entry error; see “Data Entry Errors” on page 2.<br />

EQQA311E DBCS PART OF BRACKETED FIELD IS BLANK<br />

Explanation: Data entry error; see “Data Entry Errors” on page 2.<br />

EQQA314E THE OWNER ID IS NOT SPECIFIED<br />

Explanation: Data entry error; see “Data Entry Errors” on page 2.<br />