<strong>ProSafe</strong> <strong>7000</strong> <strong>Managed</strong> <strong>Switch</strong> Release 8.0.3<br />

Code Mismatch<br />

If a switch is added to a stack and it does not have the same version of code as that of the<br />

master, the following occurs:<br />

• The new unit boots up and becomes a member of the stack.<br />

• Ports on the added unit remain in the detached state.<br />

• A message displays on the CLI indicating a code mismatch with the newly added unit.<br />

• To have the newly added unit to merge normally with the stack, use the copy command to<br />

load the correct code from the master to the newly added unit. Then reset the newly<br />

added member. It should reboot normally and join the stack.<br />

Upgrade the Firmware<br />

All stack members must run the same firmware version. Ports on stack members that don’t<br />

match the master switch firmware version don’t come up and the show switch command<br />

shows a code mismatch error.<br />

1. <strong>NETGEAR</strong> recommends that you schedule the firmware upgrade when there is no<br />

excessive network traffic (such as a broadcast event).<br />

2. Download new firmware using TFTP or xmodem to the master switch using the copy<br />

command.<br />

Once the firmware is successfully loaded on the master switch, it automatically<br />

propagates to the other units in the stack.<br />

CAUTION:<br />

To avoid errors during code propagation, do not move stack cables or<br />

reconfigure units.<br />

3. If an error occurs during code propagation, first check to make sure the master switch is<br />

running the correct firmware. Then issue the copy command (in stack configuration mode)<br />

to make another attempt to copy the firmware to the units that did not get updated.<br />

4. Once code is loaded to all members of the stack, reset all the switches so that the new<br />

firmware starts running.<br />

Migrate Configuration with a Firmware Upgrade<br />

In some cases, a configuration might not be carried forward in a code update. For updates<br />

where this issue is to be expected, the following procedure should be followed:<br />

1. Save the current configuration by uploading it from the stack, using the copy command<br />

from the CLI.<br />

2. Load new code into the stack manager. Reboot the stack.<br />

3. Upon reboot, go into the boot menu and erase the configuration (restore to factory defaults)<br />

Chapter 18. <strong>Switch</strong> Stacks<br />

| 307

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!