05.03.2013 Views

ProSafe 7000 Managed NETGEAR Switch Software Administration ...

ProSafe 7000 Managed NETGEAR Switch Software Administration ...

ProSafe 7000 Managed NETGEAR Switch Software Administration ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Web Interface: Add a New Community<br />

322 | Chapter 19. SNMP<br />

<strong>ProSafe</strong> <strong>7000</strong> <strong>Managed</strong> <strong>Switch</strong> Release 8.0.3<br />

1. Select System > SNMP > SNMP V1/V2 > Community Configuration. A screen similar<br />

to the following displays.<br />

2. In the Community Name field, enter public@4.<br />

3. In the Client Address field, enter 0.0.0.0.<br />

4. In the Client IP Mask field, enter 0.0.0.0.<br />

5. In the Access Mode field, select Read/Write.<br />

6. In the Status field, select Enable.<br />

7. Click Add.<br />

Enable SNMP Trap<br />

The example is shown as CLI commands and as a Web interface procedure.<br />

CLI: Enable SNMP Trap<br />

This example shows how to send SNMP trap to the SNMP server.<br />

(Netgear switch) #config<br />

(Netgear switch) (Config)# snmptrap public 10.100.5.17<br />

Enable send trap to SNMP server 10.100.5.17<br />

(Netgear switch) (Config)#snmp-server traps linkmode<br />

Enable send link status to the SNMP server when<br />

link status changes.