06.03.2013 Views

ATTIX 751-01/-11 - Nilfisk-ALTO

ATTIX 751-01/-11 - Nilfisk-ALTO

ATTIX 751-01/-11 - Nilfisk-ALTO

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Nilfisk</strong><br />

<strong>ALTO</strong><br />

7.7 Checking electronic flow metering EC in automatic mode<br />

(Attix 791-2M/B1)<br />

L1<br />

Power line<br />

N<br />

Attix7_ver.1.0_14<strong>01</strong>05<br />

Troubleshooting<br />

Terminal EC electronics E<br />

1. Make sure the unit is isolated from the power.<br />

2. Remove the hood (see 4.4).<br />

3. Set the cleaner head on a clean container<br />

(w/o a filter bag) and withdraw the hose from the<br />

container fitting.<br />

4. Insert the “tool” lamp in the socket (302000765) and<br />

rotate the bulb one turn out of the receptacle.<br />

5. Apply line voltage and set the switch to “Auto”.<br />

6. Visual check:<br />

Green LED flashes (standby).<br />

7. Check:<br />

Turn the bulb properly into the receptacle. The “tool”<br />

lamp illuminates immediately, and the motor starts.<br />

The red, yellow and green LEDs illuminate.<br />

The red and yellow LEDs extinguish after 3-5 s.<br />

Rotate the bulb one turn out of the receptacle.<br />

The motor stops (runs on) after 3-5 s.<br />

“Auto” Mode OK?<br />

Lamp<br />

Tool<br />

302000765<br />

Yes - “Auto” Mode OK.<br />

No - Replace electronic<br />

and recalibrate<br />

LED red LED yellow<br />

LED green<br />

38/59<br />

Troubleshooting