2. Technical Data<br />
4<br />
MDC-12.004-AS MDC-12.005-AS<br />
Mains - voltage 230V AC;115V AC o.r. 230V AC; 115VAC o.r.<br />
Tolerance of the mains-voltage +/- 15% +/- 15%<br />
Frequency of the mains-voltage 50 – 60 Hz 50 – 60 Hz<br />
Recommended fuse in the mains 6,3A slow 10A slow<br />
Rec. max. motor size 375 Watt 550 Watt<br />
Nominal voltage of the motor 3x230V AC 3x230V AC<br />
Motor-current (max. at 30°C case-temp.) 3A RMS 5,5A RMS<br />
(max. at 80°C case-temp.) 2,4 A RMS 4,4A RMS<br />
Temperature-range (case-temperature) 0 – 80°C 0 – 80°C<br />
Mechanical size (LxBxT) [mm] 150x100x70 150x100x70<br />
Weight [kg]<br />
Output - <strong>frequency</strong> - ranges:<br />
0,85 0,88<br />
• Normal – operation 0 - 150 Hz<br />
• High - <strong>frequency</strong> – operation<br />
0 - 300 Hz<br />
Adjustment - range of the min. <strong>frequency</strong><br />
0-50% of the pre-adjusted maximum<br />
Ramp - times:<br />
Normal-operation, <strong>frequency</strong>-step=150Hz<br />
• With short ramp 0,2 – 15 sec<br />
• With long ramp 4 – 300 sec<br />
High-<strong>frequency</strong>-mode, freq. step = 600Hz<br />
• With short ramp 0,2 – 15 sec<br />
• With long ramp 4 – 300 sec<br />
Pump-operation-mode, freq. step = 55 Hz 5 sec<br />
200 Hz – Operation - mode 1 sec<br />
Control - signals:<br />
• B1 and B2 open Potentiometer or ext. voltage 0-10V<br />
• B1 closed, B2 open 0-20mA<br />
• B1 and B2 closed 4-20mA<br />
Input-resistance of the control-input:<br />
B1 open >500kOhm<br />
B1 closed 470 Ohm<br />
Enable - signal: closed loop with less than 1 kohm<br />
current in the enable - loop 10V/1mA DC<br />
Reversing - signal: open / closed loop, 10 V / 1mA DC<br />
Technical Documentation Frequency inverter MFR-<strong>22</strong>/600/1500<br />