Linear Motor Actuators GLM10,15,20,25 - Thk.com
Linear Motor Actuators GLM10,15,20,25 - Thk.com
Linear Motor Actuators GLM10,15,20,25 - Thk.com
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Main unit<br />
Driver<br />
Power cable D00 : No power cable required<br />
D01 : Cable length 1m<br />
D03 : Cable length 3m<br />
D05 : Cable length 5m<br />
D10 : Cable length 10m<br />
D<strong>15</strong> : Cable length <strong>15</strong>m<br />
Model no. TD : Driver model code<br />
Capacity 010CU : 100W (for S type motor)<br />
0<strong>20</strong>CU : <strong>20</strong>0W (for M type motor)<br />
Input power 100AC : Single-phase 100VAC<br />
<strong>20</strong>0AC : Single-phase/three-phase <strong>20</strong>0VAC<br />
<strong>Motor</strong> type G<strong>15</strong>SU : GLM<strong>15</strong> S type<br />
G<strong>15</strong>MU : GLM<strong>15</strong> M type<br />
Resolution<br />
(value + unit)<br />
Note: For the <strong>com</strong>binations of the power cable and encoder/magnetic pole sensor<br />
cables, see Pages 23 and 24.<br />
Encoder cable E00 : Encoder cable not required<br />
E01 : Cable length 1m<br />
E03 : Cable length 3m<br />
E05 : Cable length 5m<br />
E10 : Cable length 10m<br />
E<strong>15</strong> : Cable length <strong>15</strong>m<br />
* When the resolution is specified as NN, NU, or NV and the magnetic pole sensor<br />
code is specified as N<br />
[ KET cable (specified length) is included.<br />
* When the resolution is specified as NN, NU, or NV and the magnetic pole sensor<br />
code is specified as J<br />
[ KJET cable (specified length) is included.<br />
* When the resolution<br />
specified as N<br />
is specified as TD and the magnetic pole sensor code is<br />
[ KSET cable (1m) and CK cable (specified length) are included. CE09 cable is<br />
not included.<br />
* When the resolution<br />
specified as J<br />
is specified as TD and the magnetic pole sensor code is<br />
[ KSJT cable (interpolator side - 1m/magnetic pole sensor side - specified length)<br />
and CK cable (specified length) are included. CE09 cable is not included.<br />
Note: For the <strong>com</strong>binations of the power cable and encoder/magnetic pole sensor<br />
cables, see Pages 23 and 24.<br />
Conforming product/<br />
certified product code<br />
CU : UL Certified products & CE Marked products<br />
UL : UL Certified products only (without cable carrier)<br />
Note: Main unit must <strong>com</strong>e with a cable carrier in order for it to conform to UL Certifications<br />
and CE Marking. (Items conforming to CE Marking requirements have a protective<br />
cover on the cable connector) Also, please note that the main unit without the cable<br />
carrier only conforms to UL Certification.<br />
TD - 010CU - <strong>20</strong>0AC - G<strong>15</strong>SU - 1U - N<br />
10U : 10.0μm<br />
1U : 1.0μm<br />
500N : 0.5μm<br />
100N : 0.1μm<br />
Magnetic pole sensor J : With magnetic pole sensor equipped<br />
N : No magnetic pole sensor<br />
GLM<strong>20</strong> GLM<strong>15</strong> <strong>GLM10</strong><br />
GLM<strong>25</strong><br />
Driver Model TD<br />
<strong>20</strong>