STITCH FASTENER<br />

(2'-6" ON CENTER)<br />

RAKE TRIM<br />

(EW1-EW4)<br />

GABLE<br />

ANGLE<br />

STITCH<br />

FASTENER<br />

3'-0" O.C.<br />

TRIM TF20<br />

(STITCH FASTENER<br />

3'-0" ON CENTER)<br />

SOFFIT PANEL<br />

(SELF-DRILLER<br />

12" ON CENTER<br />

AT PURLIN OR<br />

EAVE STRUT)<br />

PURLIN EXTENSION WITH SOFFIT PANELS<br />

(SHEETED ENDWALL) (RIBBED ROOF)<br />

SELF-DRILLERS<br />

(3'-0" ON CENTER)<br />

TRIM FLASHING<br />

TF10 OR TF86<br />

(STITCH FASTENERS<br />

3'-0" ON CENTER)<br />

WALL PANEL<br />

(SELF-DRILLER<br />

2 PER FLAT)<br />

ROOF PANEL<br />

TF19 (FOR<br />

INSULATED<br />

BUILDINGS)<br />

SHT. NO.<br />

GABLE ANGLE<br />

FA1<br />

DATE<br />

REV.<br />

MAY 03 00<br />

(ONE SELF-DRILLER<br />

PER ROOF MEMBER)<br />

2 SELF-DRILLER<br />

PER PANEL FLAT


CANOPY<br />

RAFTER<br />

HIGH SIDE CANOPY<br />

SELF-DRILLERS - (SEE MA030401/<br />

MA030501) EAVE CLOSURE<br />

REQUIRED WITH SEALED EAVE<br />

OR CANOPY WITH SOFFIT<br />

GUTTER CLIP<br />

3'-0" O.C.<br />

EAVE GUTTER<br />

(EG2-4)<br />

EAVE FLASHING<br />

(SF70, SF71)<br />

TF11 OR TF10<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

NOTE: 3 FASTENERS PER JOINT OF<br />

DOWNSPOUTS. CAULK ALL JOINTS<br />

OF HORIZONTAL DOWNSPOUTS.<br />

3<br />

4 " A325<br />

BOLTS EAVE<br />

EAVE DETAIL<br />

EAVE LINE-EXPOSED CANOPY RAFTER<br />

W/GUTTER AND SOFFIT PANEL<br />

(RIBBED ROOF)<br />

STRUT<br />

TF72<br />

ST FASTENER<br />

(1'-0" O.C.)<br />

TF10<br />

OR TF11<br />

SHT. NO.<br />

FA5<br />

DATE<br />

REV.<br />

MAR. 06 00<br />

RAFTER<br />

SUPPORT<br />

DEPTH OF<br />

RAFTER<br />

WALL PANEL CUT OUT<br />

MAJOR RIB AS REQUIRED<br />

TO RECEIVE RAFTER.<br />

BOLT UP RAFTER AND<br />

CAULK.<br />

PREPARATION OF MAJOR<br />

SOFFIT<br />

PANELS<br />

RIB FOR RAFTER<br />

FASTENERS AND<br />

CLOSURE (SEE<br />

MA030401/MA030501)<br />

EAVE<br />

STRUT<br />

1<br />

2 " A325<br />

BOLTS<br />

DETAIL AT WALL LINE<br />

NOTE: ERECTOR TO FIELD "PITCH" SHEETS AT GUTTER<br />

3<br />

4 " A325 BOLTS


EAVE<br />

GUTTER<br />

CANOPY<br />

RAFTER<br />

EAVE<br />

STRUT<br />

SELF-DRILLERS - (SEE<br />

MA030401/MA030501) EAVE<br />

CLOSURE REQUIRED WITH SEALED<br />

EAVE OR CANOPY WITH SOFFIT<br />

GUTTER CLIP<br />

3'-0" O.C.<br />

EAVE GUTTER<br />

(EG2-4)<br />

EAVE FLASHING<br />

(SF70, SF71)<br />

TF11 OR TF10<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

NOTE: 3 FASTENERS PER JOINT OF<br />

DOWNSPOUTS. CAULK ALL JOINTS<br />

OF HORIZONTAL DOWNSPOUTS.<br />

EAVE DETAIL<br />

EAVE LINE-EXPOSED CANOPY RAFTER<br />

W/GUTTER AND SOFFIT AT OPEN WALL<br />

(RIBBED ROOF)<br />

EAVE LINE CANOPY<br />

3 "<br />

4<br />

DIA.<br />

A325 BOLTS<br />

FASTENERS<br />

AND CLOSURES<br />

(SEE MA030401/<br />

MA030501)<br />

EAVE FLASHING<br />

(SF70, SF71)<br />

FASTENER<br />

(1'-0" O.C.)<br />

TF72<br />

TF10<br />

DETAIL AT WALL LINE<br />

NOTE: ERECTOR TO FIELD "PITCH" SHEETS AT GUTTER<br />

OR<br />

TF11<br />

SOFFIT<br />

PANELS<br />

EAVE<br />

STRUT<br />

SHT. NO.<br />

DATE<br />

EAVE<br />

FA6<br />

REV.<br />

MAR. 06 00<br />

STRUT<br />

1 "<br />

2<br />

DIA.<br />

A325 BOLTS<br />

3 "<br />

4<br />

DIA.<br />

A325 BOLTS


CANOPY<br />

RAFTER<br />

HIGH SIDE CANOPY<br />

SELF-DRILLERS - (SEE MA030401/<br />

MA030501) EAVE CLOSURE<br />

REQUIRED WITH SEALED EAVE<br />

GUTTER CLIP<br />

3'-0" O.C.<br />

EAVE GUTTER<br />

(EG2-4)<br />

EAVE FLASHING<br />

(SF70, SF71)<br />

NOTE: 3 FASTENERS PER JOINT OF<br />

DOWNSPOUTS. CAULK ALL JOINTS<br />

OF HORIZONTAL DOWNSPOUTS.<br />

EAVE DETAIL<br />

EAVE LINE-EXPOSED CANOPY RAFTER<br />

W/GUTTER AND NO SOFFIT PANELS<br />

(RIBBED ROOF)<br />

3 " DIA.<br />

4<br />

A325<br />

BOLTS<br />

FASTENER<br />

(1'-0" O.C)<br />

EAVE<br />

STRUT<br />

3 "<br />

4<br />

DIA.<br />

A325 BOLTS<br />

FASTENERS AND<br />

CLOSURE (SEE<br />

MA030401/MA030501)<br />

EAVE TRIM<br />

(SF52)<br />

NOTE: ERECTOR TO FIELD "PITCH" SHEETS AT GUTTER<br />

SHT. NO.<br />

DATE<br />

REV.<br />

MAR. 06 00<br />

PREPARATION OF MAJOR<br />

RIB FOR RAFTER<br />

RAFTER<br />

FA7<br />

SUPPORT<br />

WALL PANEL CUT OUT<br />

DEPTH OF<br />

RAFTER<br />

MAJOR RIB AS REQUIRED<br />

TO RECEIVE RAFTER.<br />

BOLT UP RAFTER AND CAULK.<br />

EAVE<br />

STRUT<br />

1 "<br />

2<br />

DIA.<br />

A323 BOLTS<br />

DETAIL AT WALL LINE


EAVE<br />

GUTTER<br />

CANOPY<br />

NOTE: 3 FASTENERS PER JOINT<br />

OF DOWNSPOUTS. CAULK ALL<br />

JOINTS OF HORIZONTAL<br />

DOWNSPOUTS.<br />

RAFTER<br />

EAVE<br />

STRUT<br />

SELF-DRILLERS<br />

(SEE MA030401/<br />

MA030501) EAVE<br />

CLOSURE REQUIRED<br />

WITH SEALED EAVE<br />

GUTTER CLIP<br />

3'-0" O.C.<br />

EAVE<br />

GUTTER<br />

(EG2-4)<br />

EAVE FLASHING<br />

(SF70, SF71)<br />

EAVE DETAIL<br />

EAVE LINE-EXPOSED CANOPY RAFTER<br />

W/GUTTER AND NO SOFFIT AT OPEN WALL<br />

(RIBBED ROOF)<br />

EAVE LINE CANOPY<br />

EAVE FLASHING<br />

(SF70, SF71)<br />

FASTENER<br />

(1'-0" O.C.)<br />

3 "<br />

4<br />

DIA.<br />

A325 BOLTS<br />

3 "<br />

4<br />

DIA.<br />

A325 BOLTS<br />

EAVE<br />

STRUT<br />

DETAIL AT WALL LINE<br />

NOTE: ERECTOR TO FIELD "PITCH" SHEETS AT GUTTER<br />

EAVE<br />

STRUT<br />

SHT. NO.<br />

DATE<br />

FASTENERS<br />

AND CLOSURE<br />

FA8<br />

(SEE MA030401/<br />

MA030501)<br />

1 "<br />

2<br />

DIA.<br />

A325 BOLTS<br />

MAR. 06 00


CANOPY<br />

RAFTER<br />

HIGH SIDE CANOPY<br />

STITCH FASTENERS<br />

(2 PER FOOT)<br />

SELF-DRILLERS<br />

(SEE MA030401/<br />

MA030501)<br />

HIGH SIDEWALL<br />

FLASHING (SF9)<br />

(STITCH FASTENERS<br />

3'-0" O.C.)<br />

EAVE FLASHING<br />

(SF90, SF91)<br />

TF11 OR TF10<br />

STITCH FASTENERS<br />

(3'-0" O.C.) CANOPY<br />

HIGH SIDE DETAIL<br />

HIGH SIDE EXPOSED CANOPY RAFTER<br />

3 " DIA.<br />

4<br />

A325 BOLTS<br />

RAFTER<br />

WITH WALL PANEL<br />

(RIBBED ROOF)<br />

EAVE<br />

STRUT<br />

SEE DETAIL (MA030701)<br />

FOR OUTSIDE CLOSURE<br />

INSTALLATION<br />

ST FASTENER<br />

(1'-0" O.C.)<br />

TF72<br />

SOFFIT<br />

SHT. NO.<br />

DATE<br />

FA9<br />

REV.<br />

MAR. 06 00<br />

RAFTER<br />

SUPPORT<br />

DEPTH OF<br />

RAFTER<br />

WALL PANEL CUT OUT<br />

MAJOR RIB AS REQUIRED<br />

TO RECEIVE RAFTER.<br />

BOLT UP RAFTER AND CAULK.<br />

PREPARATION OF MAJOR<br />

TF10<br />

PANELS<br />

OR<br />

TF11<br />

RIB FOR RAFTER<br />

FASTENERS AND<br />

CLOSURE (SEE<br />

MA030401/MA030501)<br />

EAVE<br />

STRUT<br />

1 "<br />

2<br />

DIA.<br />

A325 BOLTS<br />

3<br />

4 " DIA.<br />

A325 BOLTS<br />

DETAIL AT WALL LINE


CANOPY<br />

RAFTER<br />

STITCH FASTENERS<br />

(2 PER FOOT)<br />

SELF-DRILLERS<br />

(SEE PT1/PT2)<br />

HIGH SIDEWALL<br />

FLASHING (SF9)<br />

(STITCH FASTENERS<br />

3'-0" ON CENTER)<br />

EAVE FLASHING<br />

(SF90, SF91)<br />

TF10 OR TF11<br />

STITCH FASTENERS<br />

EAVE<br />

STRUT<br />

CANOPY RAFTER<br />

HIGH SIDE DETAIL<br />

HIGH SIDE EXPOSED CANOPY RAFTER<br />

HIGH SIDE CANOPY<br />

SEE DETAIL MA030701 FOR<br />

CLOSURE INSTALLATION<br />

EAVE TRIM<br />

(SF90, SF91)<br />

FASTENER<br />

(1'-0" ON<br />

CENTER)<br />

WITH NO WALL PANELS<br />

(RIBBED ROOF)<br />

TF72<br />

(3'-0" ON CENTER) SOFFIT<br />

3<br />

4 " A325<br />

BOLTS<br />

TF10<br />

OR TF11<br />

PANELS<br />

3<br />

4 " A325<br />

BOLTS<br />

SHT. NO.<br />

DATE<br />

DETAIL AT WALL LINE<br />

REV.<br />

MAR. 06 00<br />

EAVE STRUT<br />

SELF-DRILLERS<br />

(SEE MA030401/<br />

MA030501)<br />

EAVE<br />

STRUT<br />

1<br />

2 " A325<br />

BOLTS<br />

FA10<br />

STITCH FASTENERS<br />

(3'-0" ON CENTER)


BASE FLASHING<br />

(2 FASTENERS<br />

PER FOOT)<br />

CANOPY<br />

RAFTER<br />

SELF-DRILLERS (SEE<br />

MA030401/MA030501)<br />

EAVE CLOSURE REQUIRED<br />

WITH SEALED EAVE OR<br />

CANOPY WITH SOFFIT<br />

GUTTER CLIP<br />

3'-0" O.C.<br />

EAVE<br />

GUTTER<br />

(EG2-4)<br />

EAVE FLASHING<br />

(SF90, SF91)<br />

TF10 OR TF11<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

CL493<br />

NOTE: 3 FASTENERS PER JOINT OF<br />

DOWNSPOUTS. CAULK ALL JOINTS OF<br />

HORIZONTAL DOWNSPOUTS.<br />

EAVE DETAIL<br />

BELOW EAVE LINE EXPOSED CANOPY<br />

RAFTER W/SHEETED WALL BELOW<br />

BASE FLASHING<br />

(BF76) STITCH<br />

FASTENER (6"<br />

ON CENTER)<br />

SEE DETAIL<br />

MA030701<br />

3 " DIA.<br />

4<br />

A325<br />

BOLTS<br />

ST FASTENER<br />

(1'-0 O.C.)<br />

(RIBBED ROOF)<br />

ST FASTENERS<br />

(2 PER FOOT)<br />

CANOPY<br />

RAFTER<br />

TF10<br />

SOFFIT<br />

PANELS<br />

OR TF11<br />

NOTE: ERECTOR TO FIELD "PITCH" ROOF SHEETS AT EAVE GUTTER<br />

SHT. NO.<br />

DATE<br />

FA11<br />

REV.<br />

MAR. 06 00<br />

DEPTH OF<br />

RAFTER<br />

WALL PANEL CUT OUT<br />

MAJOR RIB AS REQUIRED<br />

TO RECEIVE RAFTER.<br />

BOLT UP RAFTER AND<br />

CAULK.<br />

TF72<br />

RAFTER<br />

SUPPORT<br />

PREPARATION OF MAJOR<br />

RIB FOR RAFTER<br />

GIRT WITH 25 "<br />

8<br />

X 4"<br />

ANGLE (ATTACH ANGLE<br />

TO GIRT WITH FASTENERS<br />

ONE PER FOOT)<br />

INSIDE CLOSURE<br />

ST FASTENERS<br />

(ONE PER FOOT)<br />

25 "<br />

8<br />

X 4"<br />

ANGLE<br />

3 "<br />

4<br />

DIA. A325<br />

BOLTS<br />

DETAIL AT WALL LINE


BASE FLASHING<br />

(2 FASTENERS<br />

PER FOOT)<br />

CANOPY<br />

RAFTER<br />

SELF-DRILLERS (SEE<br />

MA030401/MA030501)<br />

EAVE CLOSURE REQUIRED<br />

WITH SEALED EAVE OR<br />

CANOPY WITH SOFFIT<br />

GUTTER CLIP<br />

3'-0" O.C.<br />

EAVE<br />

GUTTER<br />

(EG2-4)<br />

EAVE FLASHING<br />

(SF90, SF91)<br />

TF10 OR TF11<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

NOTE: 3 FASTENERS PER JOINT OF<br />

DOWNSPOUTS. CAULK ALL JOINTS OF<br />

HORIZONTAL DOWNSPOUTS.<br />

BASE FLASHING<br />

(BF76) STITCH<br />

FASTENER (6" O.C.)<br />

SEE DETAIL<br />

MA030701<br />

EAVE DETAIL<br />

BELOW EAVE LINE EXPOSED CANOPY<br />

ST FASTENER<br />

(1'-0" O.C.)<br />

RAFTER AND OPEN BELOW<br />

(RIBBED ROOF)<br />

3 " DIA.<br />

4<br />

A325<br />

BOLTS<br />

SELF-DRILLERS<br />

(2 PER FOOT)<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

SOFFIT<br />

CANOPY<br />

RAFTER<br />

PANELS<br />

PREPARATION OF MAJOR<br />

RIB FOR RAFTER<br />

CL493<br />

DETAIL AT WALL LINE<br />

NOTE: ERECTOR TO FIELD "PITCH" ROOF SHEETS AT EAVE GUTTER<br />

REV.<br />

MAR. 06 00<br />

DEPTH OF<br />

RAFTER<br />

WALL PANEL CUT OUT<br />

MAJOR RIB AS REQUIRED<br />

TO RECEIVE RAFTER.<br />

BOLT UP RAFTER AND<br />

CAULK.<br />

RAFTER<br />

SUPPORT<br />

SHT. NO.<br />

DATE<br />

GIRT WITH 25 "<br />

8<br />

X 4"<br />

ANGLE (ATTACH ANGLE<br />

TO GIRT WITH FASTENERS<br />

ONE PER FOOT)<br />

INSIDE CLOSURE<br />

FA12<br />

SELF-DRILLERS<br />

(ONE PER FOOT)<br />

TF10 OR TF11<br />

3<br />

4 " DIA. A325<br />

BOLTS


FASTENERS AND CLOSURE<br />

(SEE MA030401/MA030501)<br />

EAVE CLOSURE REQUIRED<br />

WITH SEALED EAVE OR<br />

CANOPY WITH SOFFIT<br />

EAVE GUTTER<br />

(EG2-EG4)<br />

NOTE: ERECTOR TO<br />

FIELD "PITCH" ROOF<br />

SHEETS AT EAVE<br />

GUTTER<br />

EAVE FLASHING<br />

(SF70, SF71)<br />

TF10 or TF11<br />

STITCH FASTENERS<br />

(3'-0 O.C.)<br />

SOFFIT PANELS<br />

EAVE STRUT<br />

1<br />

2 " A325<br />

BOLTS<br />

RIGID FRAME<br />

COLUMN<br />

EAVE LINE FLUSH CANOPY RAFTER<br />

FASTENERS AND CLOSURE<br />

(SEE MA030401/MA030501)<br />

EAVE STRUT<br />

STITCH FASTENERS<br />

(1'-0 O.C.)<br />

1<br />

2 " A325<br />

BOLTS<br />

TF10 OR TF11<br />

STITCH FASTENERS<br />

(3'-0 O.C.)<br />

STITCH FASTENERS<br />

(1'-0 O.C.)<br />

CANOPY RAFTER<br />

AT SHEETED WALL<br />

(RIBBED ROOF)<br />

TF72<br />

1<br />

2 " A325<br />

BOLTS<br />

SEE "CROSS SECTION"<br />

FOR BOLT SIZE AND<br />

REV.<br />

Dec. 09 01<br />

QUANTITY<br />

CANOPY RAFTER<br />

DETAIL AT CANOPY RAFTER CONN.<br />

WHEN COL. DEPTH IS 1'-3" OR GREATER<br />

DETAIL AT CANOPY RAFTER CONN.<br />

SHT. NO.<br />

DATE<br />

1<br />

2 " A325 BOLTS<br />

WHEN COL. DEPTH IS 1'-3" OR GREATER<br />

FA13


SEE DETAIL MA030701<br />

FOR OUTSIDE CLOSURE<br />

INSTALLATION<br />

STITCH FASTENERS<br />

(2 PER FOOT)<br />

HIGH SIDEWALL<br />

TRIM (SF9)<br />

(STITCH FASTENERS<br />

3'-0" O.C.)<br />

EAVE FLASHING<br />

(SF90, SF91)<br />

TF10 or TF11<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

SELF-DRILLERS<br />

(1'-0" O.C.)<br />

EAVE STRUT<br />

1<br />

2 " A325<br />

BOLTS<br />

RIGID FRAME<br />

COLUMN<br />

HIGH SIDE EAVE LINE FLUSH CANOPY<br />

1<br />

2 " A325<br />

BOLTS<br />

SOFFIT PANELS<br />

TF72<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

EAVE STRUT<br />

STITCH FASTENERS<br />

(1'-0 O.C.)<br />

STITCH FASTENERS<br />

(1'-0" O.C.)<br />

RAFTER AT SHEETED WALL<br />

(RIBBED ROOF)<br />

TF10 OR TF11<br />

1<br />

2 " A325<br />

BOLTS<br />

FASTENERS AND CLOSURE<br />

REV.<br />

Dec. 09 01<br />

(SEE MA030401/MA030501)<br />

CANOPY<br />

RAFTER<br />

1<br />

2 " A325<br />

BOLTS<br />

CANOPY<br />

RAFTER<br />

DETAIL AT CANOPY RAFTER CONN.<br />

WHEN COL. DEPTH IS 1'-3" OR GREATER<br />

DETAIL AT CANOPY RAFTER CONN.<br />

SHT. NO.<br />

DATE<br />

SEE "CROSS SECTION"<br />

FOR BOLT SIZE AND<br />

QUANTITY<br />

WHEN COL. DEPTH IS 1'-3" OR GREATER<br />

FA15


SEE DETAIL MA030701<br />

FOR OUTSIDE CLOSURE<br />

INSTALLATION<br />

STITCH FASTENERS<br />

(2 PER FOOT)<br />

HIGH SIDEWALL<br />

TRIM (SF9)<br />

(STITCH FASTENERS<br />

3'-0" 0.C.)<br />

EAVE FLASHING<br />

(SF90, SF91)<br />

TF10 OR TF11<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

SELF-DRILLERS<br />

(1'-0" O.C.)<br />

EAVE<br />

STRUT<br />

1 " DIA.<br />

2<br />

A325 BOLTS<br />

RIGID FRAME<br />

COLUMN<br />

HIGH SIDE EAVE LINE FLUSH<br />

CANOPY RAFTER AT OPEN WALL<br />

(RIBBED ROOF)<br />

1 " A325<br />

2<br />

BOLTS<br />

EAVE STRUT<br />

1 "<br />

2<br />

DIA.<br />

A325 BOLTS<br />

TF10 OR TF11<br />

STITCH FASTENERS<br />

(1'-0" O.C.)<br />

SOFFIT PANELS<br />

TF72<br />

1 "<br />

2<br />

DIA.<br />

A325 BOLTS<br />

1 " DIA.<br />

2<br />

A325<br />

BOLTS<br />

REV.<br />

Dec. 09 01<br />

DETAIL AT CANOPY RAFTER CONN.<br />

WHEN COL. DEPTH IS 1'-3" OR GREATER<br />

DETAIL AT CANOPY RAFTER CONN.<br />

WHEN COL. DEPTH IS 1'-3" OR GREATER<br />

SHT. NO.<br />

DATE<br />

SELF-DRILLERS (SEE<br />

MA030401/MA030501)<br />

SEE "CROSS SECTION"<br />

FOR BOLT SIZE AND<br />

QUANTITY<br />

CANOPY RAFTER<br />

FA16<br />

CANOPY<br />

RAFTER


NOTE: ERECTOR<br />

TO FIELD "PITCH"<br />

ROOF SHEETS AT<br />

EAVE GUTTER<br />

EAVE GUTTER<br />

(EG2-4)<br />

EAVE FLASHING<br />

(SF70, SF71)<br />

TF10 OR TF11<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

CANOPY<br />

RAFTER<br />

BELOW EAVE LINE<br />

FLUSH CANOPY RAFTER AT SHEETED WALL<br />

(RIBBED ROOF)<br />

SELF-DRILLERS (SEE<br />

MA030401/MA030501)<br />

EAVE CLOSURE REQUIRED<br />

WITH SEALED EAVE OR<br />

CANOPY WITH SOFFIT<br />

PURLIN<br />

CL200<br />

1 " BOLTS<br />

2<br />

TF72<br />

SOFFIT PANELS<br />

CL200<br />

TF10 OR<br />

TF11<br />

SHT. NO.<br />

DATE<br />

FA17<br />

REV.<br />

MAR. 06 00<br />

BASE FLASHING (BF76)<br />

(SEE DETAIL MA030701)<br />

SELF-DRILLERS<br />

(2 PER FOOT)<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

GIRT<br />

ANGLE<br />

SELF-DRILLERS<br />

(2 PER FOOT)<br />

STITCH FASTENERS<br />

(1'-0" O.C.)<br />

COLUMN<br />

3 "<br />

4<br />

DIA.<br />

A325 BOLTS


NOTE: ERECTOR TO FIELD<br />

"PITCH" ROOF SHEETS AT<br />

EAVE GUTTER<br />

SELF-DRILLERS (SEE<br />

MA030401/MA030501)<br />

EAVE CLOSURE REQUIRED<br />

WITH SEALED EAVE<br />

EAVE<br />

GUTTER<br />

(EG2-4)<br />

EAVE FLASHING<br />

(SF70)<br />

STITCH FASTENERS<br />

(3'-0" O.C.)<br />

PURLIN<br />

CANOPY<br />

RAFTER<br />

BELOW EAVE LINE<br />

FLUSH CANOPY RAFTER AT OPEN WALL<br />

(RIBBED ROOF)<br />

1 " BOLTS<br />

2<br />

CL200<br />

BASE FLASHING (BF76)<br />

(SEE DETAIL MA030701)<br />

CL200<br />

3 " A325<br />

4<br />

BOLTS<br />

SELF-DRILLERS<br />

(2 PER FOOT)<br />

CANOPY<br />

RAFTER<br />

SHT. NO.<br />

DATE<br />

FA18<br />

REV.<br />

MAR. 06 00<br />

GIRT<br />

COLUMN


EAVE STRUT<br />

CHANNEL<br />

1 " DIA.<br />

2<br />

A325 BOLTS<br />

RIGID FRAME<br />

COLUMN<br />

PURLIN SUPPORT CHANNEL DETAIL<br />

SHT. NO.<br />

DATE<br />

PURLIN<br />

FA35<br />

REV.<br />

MAR. 06 00<br />

ST FASTENERS