Canopy Detail - Ceco Building Systems
Canopy Detail - Ceco Building Systems
Canopy Detail - Ceco Building Systems
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
STITCH FASTENER<br />
(2'-6" ON CENTER)<br />
RAKE TRIM<br />
(EW1-EW4)<br />
GABLE<br />
ANGLE<br />
STITCH<br />
FASTENER<br />
3'-0" O.C.<br />
TRIM TF20<br />
(STITCH FASTENER<br />
3'-0" ON CENTER)<br />
SOFFIT PANEL<br />
(SELF-DRILLER<br />
12" ON CENTER<br />
AT PURLIN OR<br />
EAVE STRUT)<br />
PURLIN EXTENSION WITH SOFFIT PANELS<br />
(SHEETED ENDWALL) (RIBBED ROOF)<br />
SELF-DRILLERS<br />
(3'-0" ON CENTER)<br />
TRIM FLASHING<br />
TF10 OR TF86<br />
(STITCH FASTENERS<br />
3'-0" ON CENTER)<br />
WALL PANEL<br />
(SELF-DRILLER<br />
2 PER FLAT)<br />
ROOF PANEL<br />
TF19 (FOR<br />
INSULATED<br />
BUILDINGS)<br />
SHT. NO.<br />
GABLE ANGLE<br />
FA1<br />
DATE<br />
REV.<br />
MAY 03 00<br />
(ONE SELF-DRILLER<br />
PER ROOF MEMBER)<br />
2 SELF-DRILLER<br />
PER PANEL FLAT
CANOPY<br />
RAFTER<br />
HIGH SIDE CANOPY<br />
SELF-DRILLERS - (SEE MA030401/<br />
MA030501) EAVE CLOSURE<br />
REQUIRED WITH SEALED EAVE<br />
OR CANOPY WITH SOFFIT<br />
GUTTER CLIP<br />
3'-0" O.C.<br />
EAVE GUTTER<br />
(EG2-4)<br />
EAVE FLASHING<br />
(SF70, SF71)<br />
TF11 OR TF10<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
NOTE: 3 FASTENERS PER JOINT OF<br />
DOWNSPOUTS. CAULK ALL JOINTS<br />
OF HORIZONTAL DOWNSPOUTS.<br />
3<br />
4 " A325<br />
BOLTS EAVE<br />
EAVE DETAIL<br />
EAVE LINE-EXPOSED CANOPY RAFTER<br />
W/GUTTER AND SOFFIT PANEL<br />
(RIBBED ROOF)<br />
STRUT<br />
TF72<br />
ST FASTENER<br />
(1'-0" O.C.)<br />
TF10<br />
OR TF11<br />
SHT. NO.<br />
FA5<br />
DATE<br />
REV.<br />
MAR. 06 00<br />
RAFTER<br />
SUPPORT<br />
DEPTH OF<br />
RAFTER<br />
WALL PANEL CUT OUT<br />
MAJOR RIB AS REQUIRED<br />
TO RECEIVE RAFTER.<br />
BOLT UP RAFTER AND<br />
CAULK.<br />
PREPARATION OF MAJOR<br />
SOFFIT<br />
PANELS<br />
RIB FOR RAFTER<br />
FASTENERS AND<br />
CLOSURE (SEE<br />
MA030401/MA030501)<br />
EAVE<br />
STRUT<br />
1<br />
2 " A325<br />
BOLTS<br />
DETAIL AT WALL LINE<br />
NOTE: ERECTOR TO FIELD "PITCH" SHEETS AT GUTTER<br />
3<br />
4 " A325 BOLTS
EAVE<br />
GUTTER<br />
CANOPY<br />
RAFTER<br />
EAVE<br />
STRUT<br />
SELF-DRILLERS - (SEE<br />
MA030401/MA030501) EAVE<br />
CLOSURE REQUIRED WITH SEALED<br />
EAVE OR CANOPY WITH SOFFIT<br />
GUTTER CLIP<br />
3'-0" O.C.<br />
EAVE GUTTER<br />
(EG2-4)<br />
EAVE FLASHING<br />
(SF70, SF71)<br />
TF11 OR TF10<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
NOTE: 3 FASTENERS PER JOINT OF<br />
DOWNSPOUTS. CAULK ALL JOINTS<br />
OF HORIZONTAL DOWNSPOUTS.<br />
EAVE DETAIL<br />
EAVE LINE-EXPOSED CANOPY RAFTER<br />
W/GUTTER AND SOFFIT AT OPEN WALL<br />
(RIBBED ROOF)<br />
EAVE LINE CANOPY<br />
3 "<br />
4<br />
DIA.<br />
A325 BOLTS<br />
FASTENERS<br />
AND CLOSURES<br />
(SEE MA030401/<br />
MA030501)<br />
EAVE FLASHING<br />
(SF70, SF71)<br />
FASTENER<br />
(1'-0" O.C.)<br />
TF72<br />
TF10<br />
DETAIL AT WALL LINE<br />
NOTE: ERECTOR TO FIELD "PITCH" SHEETS AT GUTTER<br />
OR<br />
TF11<br />
SOFFIT<br />
PANELS<br />
EAVE<br />
STRUT<br />
SHT. NO.<br />
DATE<br />
EAVE<br />
FA6<br />
REV.<br />
MAR. 06 00<br />
STRUT<br />
1 "<br />
2<br />
DIA.<br />
A325 BOLTS<br />
3 "<br />
4<br />
DIA.<br />
A325 BOLTS
CANOPY<br />
RAFTER<br />
HIGH SIDE CANOPY<br />
SELF-DRILLERS - (SEE MA030401/<br />
MA030501) EAVE CLOSURE<br />
REQUIRED WITH SEALED EAVE<br />
GUTTER CLIP<br />
3'-0" O.C.<br />
EAVE GUTTER<br />
(EG2-4)<br />
EAVE FLASHING<br />
(SF70, SF71)<br />
NOTE: 3 FASTENERS PER JOINT OF<br />
DOWNSPOUTS. CAULK ALL JOINTS<br />
OF HORIZONTAL DOWNSPOUTS.<br />
EAVE DETAIL<br />
EAVE LINE-EXPOSED CANOPY RAFTER<br />
W/GUTTER AND NO SOFFIT PANELS<br />
(RIBBED ROOF)<br />
3 " DIA.<br />
4<br />
A325<br />
BOLTS<br />
FASTENER<br />
(1'-0" O.C)<br />
EAVE<br />
STRUT<br />
3 "<br />
4<br />
DIA.<br />
A325 BOLTS<br />
FASTENERS AND<br />
CLOSURE (SEE<br />
MA030401/MA030501)<br />
EAVE TRIM<br />
(SF52)<br />
NOTE: ERECTOR TO FIELD "PITCH" SHEETS AT GUTTER<br />
SHT. NO.<br />
DATE<br />
REV.<br />
MAR. 06 00<br />
PREPARATION OF MAJOR<br />
RIB FOR RAFTER<br />
RAFTER<br />
FA7<br />
SUPPORT<br />
WALL PANEL CUT OUT<br />
DEPTH OF<br />
RAFTER<br />
MAJOR RIB AS REQUIRED<br />
TO RECEIVE RAFTER.<br />
BOLT UP RAFTER AND CAULK.<br />
EAVE<br />
STRUT<br />
1 "<br />
2<br />
DIA.<br />
A323 BOLTS<br />
DETAIL AT WALL LINE
EAVE<br />
GUTTER<br />
CANOPY<br />
NOTE: 3 FASTENERS PER JOINT<br />
OF DOWNSPOUTS. CAULK ALL<br />
JOINTS OF HORIZONTAL<br />
DOWNSPOUTS.<br />
RAFTER<br />
EAVE<br />
STRUT<br />
SELF-DRILLERS<br />
(SEE MA030401/<br />
MA030501) EAVE<br />
CLOSURE REQUIRED<br />
WITH SEALED EAVE<br />
GUTTER CLIP<br />
3'-0" O.C.<br />
EAVE<br />
GUTTER<br />
(EG2-4)<br />
EAVE FLASHING<br />
(SF70, SF71)<br />
EAVE DETAIL<br />
EAVE LINE-EXPOSED CANOPY RAFTER<br />
W/GUTTER AND NO SOFFIT AT OPEN WALL<br />
(RIBBED ROOF)<br />
EAVE LINE CANOPY<br />
EAVE FLASHING<br />
(SF70, SF71)<br />
FASTENER<br />
(1'-0" O.C.)<br />
3 "<br />
4<br />
DIA.<br />
A325 BOLTS<br />
3 "<br />
4<br />
DIA.<br />
A325 BOLTS<br />
EAVE<br />
STRUT<br />
DETAIL AT WALL LINE<br />
NOTE: ERECTOR TO FIELD "PITCH" SHEETS AT GUTTER<br />
EAVE<br />
STRUT<br />
SHT. NO.<br />
DATE<br />
FASTENERS<br />
AND CLOSURE<br />
FA8<br />
(SEE MA030401/<br />
MA030501)<br />
1 "<br />
2<br />
DIA.<br />
A325 BOLTS<br />
MAR. 06 00
CANOPY<br />
RAFTER<br />
HIGH SIDE CANOPY<br />
STITCH FASTENERS<br />
(2 PER FOOT)<br />
SELF-DRILLERS<br />
(SEE MA030401/<br />
MA030501)<br />
HIGH SIDEWALL<br />
FLASHING (SF9)<br />
(STITCH FASTENERS<br />
3'-0" O.C.)<br />
EAVE FLASHING<br />
(SF90, SF91)<br />
TF11 OR TF10<br />
STITCH FASTENERS<br />
(3'-0" O.C.) CANOPY<br />
HIGH SIDE DETAIL<br />
HIGH SIDE EXPOSED CANOPY RAFTER<br />
3 " DIA.<br />
4<br />
A325 BOLTS<br />
RAFTER<br />
WITH WALL PANEL<br />
(RIBBED ROOF)<br />
EAVE<br />
STRUT<br />
SEE DETAIL (MA030701)<br />
FOR OUTSIDE CLOSURE<br />
INSTALLATION<br />
ST FASTENER<br />
(1'-0" O.C.)<br />
TF72<br />
SOFFIT<br />
SHT. NO.<br />
DATE<br />
FA9<br />
REV.<br />
MAR. 06 00<br />
RAFTER<br />
SUPPORT<br />
DEPTH OF<br />
RAFTER<br />
WALL PANEL CUT OUT<br />
MAJOR RIB AS REQUIRED<br />
TO RECEIVE RAFTER.<br />
BOLT UP RAFTER AND CAULK.<br />
PREPARATION OF MAJOR<br />
TF10<br />
PANELS<br />
OR<br />
TF11<br />
RIB FOR RAFTER<br />
FASTENERS AND<br />
CLOSURE (SEE<br />
MA030401/MA030501)<br />
EAVE<br />
STRUT<br />
1 "<br />
2<br />
DIA.<br />
A325 BOLTS<br />
3<br />
4 " DIA.<br />
A325 BOLTS<br />
DETAIL AT WALL LINE
CANOPY<br />
RAFTER<br />
STITCH FASTENERS<br />
(2 PER FOOT)<br />
SELF-DRILLERS<br />
(SEE PT1/PT2)<br />
HIGH SIDEWALL<br />
FLASHING (SF9)<br />
(STITCH FASTENERS<br />
3'-0" ON CENTER)<br />
EAVE FLASHING<br />
(SF90, SF91)<br />
TF10 OR TF11<br />
STITCH FASTENERS<br />
EAVE<br />
STRUT<br />
CANOPY RAFTER<br />
HIGH SIDE DETAIL<br />
HIGH SIDE EXPOSED CANOPY RAFTER<br />
HIGH SIDE CANOPY<br />
SEE DETAIL MA030701 FOR<br />
CLOSURE INSTALLATION<br />
EAVE TRIM<br />
(SF90, SF91)<br />
FASTENER<br />
(1'-0" ON<br />
CENTER)<br />
WITH NO WALL PANELS<br />
(RIBBED ROOF)<br />
TF72<br />
(3'-0" ON CENTER) SOFFIT<br />
3<br />
4 " A325<br />
BOLTS<br />
TF10<br />
OR TF11<br />
PANELS<br />
3<br />
4 " A325<br />
BOLTS<br />
SHT. NO.<br />
DATE<br />
DETAIL AT WALL LINE<br />
REV.<br />
MAR. 06 00<br />
EAVE STRUT<br />
SELF-DRILLERS<br />
(SEE MA030401/<br />
MA030501)<br />
EAVE<br />
STRUT<br />
1<br />
2 " A325<br />
BOLTS<br />
FA10<br />
STITCH FASTENERS<br />
(3'-0" ON CENTER)
BASE FLASHING<br />
(2 FASTENERS<br />
PER FOOT)<br />
CANOPY<br />
RAFTER<br />
SELF-DRILLERS (SEE<br />
MA030401/MA030501)<br />
EAVE CLOSURE REQUIRED<br />
WITH SEALED EAVE OR<br />
CANOPY WITH SOFFIT<br />
GUTTER CLIP<br />
3'-0" O.C.<br />
EAVE<br />
GUTTER<br />
(EG2-4)<br />
EAVE FLASHING<br />
(SF90, SF91)<br />
TF10 OR TF11<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
CL493<br />
NOTE: 3 FASTENERS PER JOINT OF<br />
DOWNSPOUTS. CAULK ALL JOINTS OF<br />
HORIZONTAL DOWNSPOUTS.<br />
EAVE DETAIL<br />
BELOW EAVE LINE EXPOSED CANOPY<br />
RAFTER W/SHEETED WALL BELOW<br />
BASE FLASHING<br />
(BF76) STITCH<br />
FASTENER (6"<br />
ON CENTER)<br />
SEE DETAIL<br />
MA030701<br />
3 " DIA.<br />
4<br />
A325<br />
BOLTS<br />
ST FASTENER<br />
(1'-0 O.C.)<br />
(RIBBED ROOF)<br />
ST FASTENERS<br />
(2 PER FOOT)<br />
CANOPY<br />
RAFTER<br />
TF10<br />
SOFFIT<br />
PANELS<br />
OR TF11<br />
NOTE: ERECTOR TO FIELD "PITCH" ROOF SHEETS AT EAVE GUTTER<br />
SHT. NO.<br />
DATE<br />
FA11<br />
REV.<br />
MAR. 06 00<br />
DEPTH OF<br />
RAFTER<br />
WALL PANEL CUT OUT<br />
MAJOR RIB AS REQUIRED<br />
TO RECEIVE RAFTER.<br />
BOLT UP RAFTER AND<br />
CAULK.<br />
TF72<br />
RAFTER<br />
SUPPORT<br />
PREPARATION OF MAJOR<br />
RIB FOR RAFTER<br />
GIRT WITH 25 "<br />
8<br />
X 4"<br />
ANGLE (ATTACH ANGLE<br />
TO GIRT WITH FASTENERS<br />
ONE PER FOOT)<br />
INSIDE CLOSURE<br />
ST FASTENERS<br />
(ONE PER FOOT)<br />
25 "<br />
8<br />
X 4"<br />
ANGLE<br />
3 "<br />
4<br />
DIA. A325<br />
BOLTS<br />
DETAIL AT WALL LINE
BASE FLASHING<br />
(2 FASTENERS<br />
PER FOOT)<br />
CANOPY<br />
RAFTER<br />
SELF-DRILLERS (SEE<br />
MA030401/MA030501)<br />
EAVE CLOSURE REQUIRED<br />
WITH SEALED EAVE OR<br />
CANOPY WITH SOFFIT<br />
GUTTER CLIP<br />
3'-0" O.C.<br />
EAVE<br />
GUTTER<br />
(EG2-4)<br />
EAVE FLASHING<br />
(SF90, SF91)<br />
TF10 OR TF11<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
NOTE: 3 FASTENERS PER JOINT OF<br />
DOWNSPOUTS. CAULK ALL JOINTS OF<br />
HORIZONTAL DOWNSPOUTS.<br />
BASE FLASHING<br />
(BF76) STITCH<br />
FASTENER (6" O.C.)<br />
SEE DETAIL<br />
MA030701<br />
EAVE DETAIL<br />
BELOW EAVE LINE EXPOSED CANOPY<br />
ST FASTENER<br />
(1'-0" O.C.)<br />
RAFTER AND OPEN BELOW<br />
(RIBBED ROOF)<br />
3 " DIA.<br />
4<br />
A325<br />
BOLTS<br />
SELF-DRILLERS<br />
(2 PER FOOT)<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
SOFFIT<br />
CANOPY<br />
RAFTER<br />
PANELS<br />
PREPARATION OF MAJOR<br />
RIB FOR RAFTER<br />
CL493<br />
DETAIL AT WALL LINE<br />
NOTE: ERECTOR TO FIELD "PITCH" ROOF SHEETS AT EAVE GUTTER<br />
REV.<br />
MAR. 06 00<br />
DEPTH OF<br />
RAFTER<br />
WALL PANEL CUT OUT<br />
MAJOR RIB AS REQUIRED<br />
TO RECEIVE RAFTER.<br />
BOLT UP RAFTER AND<br />
CAULK.<br />
RAFTER<br />
SUPPORT<br />
SHT. NO.<br />
DATE<br />
GIRT WITH 25 "<br />
8<br />
X 4"<br />
ANGLE (ATTACH ANGLE<br />
TO GIRT WITH FASTENERS<br />
ONE PER FOOT)<br />
INSIDE CLOSURE<br />
FA12<br />
SELF-DRILLERS<br />
(ONE PER FOOT)<br />
TF10 OR TF11<br />
3<br />
4 " DIA. A325<br />
BOLTS
FASTENERS AND CLOSURE<br />
(SEE MA030401/MA030501)<br />
EAVE CLOSURE REQUIRED<br />
WITH SEALED EAVE OR<br />
CANOPY WITH SOFFIT<br />
EAVE GUTTER<br />
(EG2-EG4)<br />
NOTE: ERECTOR TO<br />
FIELD "PITCH" ROOF<br />
SHEETS AT EAVE<br />
GUTTER<br />
EAVE FLASHING<br />
(SF70, SF71)<br />
TF10 or TF11<br />
STITCH FASTENERS<br />
(3'-0 O.C.)<br />
SOFFIT PANELS<br />
EAVE STRUT<br />
1<br />
2 " A325<br />
BOLTS<br />
RIGID FRAME<br />
COLUMN<br />
EAVE LINE FLUSH CANOPY RAFTER<br />
FASTENERS AND CLOSURE<br />
(SEE MA030401/MA030501)<br />
EAVE STRUT<br />
STITCH FASTENERS<br />
(1'-0 O.C.)<br />
1<br />
2 " A325<br />
BOLTS<br />
TF10 OR TF11<br />
STITCH FASTENERS<br />
(3'-0 O.C.)<br />
STITCH FASTENERS<br />
(1'-0 O.C.)<br />
CANOPY RAFTER<br />
AT SHEETED WALL<br />
(RIBBED ROOF)<br />
TF72<br />
1<br />
2 " A325<br />
BOLTS<br />
SEE "CROSS SECTION"<br />
FOR BOLT SIZE AND<br />
REV.<br />
Dec. 09 01<br />
QUANTITY<br />
CANOPY RAFTER<br />
DETAIL AT CANOPY RAFTER CONN.<br />
WHEN COL. DEPTH IS 1'-3" OR GREATER<br />
DETAIL AT CANOPY RAFTER CONN.<br />
SHT. NO.<br />
DATE<br />
1<br />
2 " A325 BOLTS<br />
WHEN COL. DEPTH IS 1'-3" OR GREATER<br />
FA13
SEE DETAIL MA030701<br />
FOR OUTSIDE CLOSURE<br />
INSTALLATION<br />
STITCH FASTENERS<br />
(2 PER FOOT)<br />
HIGH SIDEWALL<br />
TRIM (SF9)<br />
(STITCH FASTENERS<br />
3'-0" O.C.)<br />
EAVE FLASHING<br />
(SF90, SF91)<br />
TF10 or TF11<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
SELF-DRILLERS<br />
(1'-0" O.C.)<br />
EAVE STRUT<br />
1<br />
2 " A325<br />
BOLTS<br />
RIGID FRAME<br />
COLUMN<br />
HIGH SIDE EAVE LINE FLUSH CANOPY<br />
1<br />
2 " A325<br />
BOLTS<br />
SOFFIT PANELS<br />
TF72<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
EAVE STRUT<br />
STITCH FASTENERS<br />
(1'-0 O.C.)<br />
STITCH FASTENERS<br />
(1'-0" O.C.)<br />
RAFTER AT SHEETED WALL<br />
(RIBBED ROOF)<br />
TF10 OR TF11<br />
1<br />
2 " A325<br />
BOLTS<br />
FASTENERS AND CLOSURE<br />
REV.<br />
Dec. 09 01<br />
(SEE MA030401/MA030501)<br />
CANOPY<br />
RAFTER<br />
1<br />
2 " A325<br />
BOLTS<br />
CANOPY<br />
RAFTER<br />
DETAIL AT CANOPY RAFTER CONN.<br />
WHEN COL. DEPTH IS 1'-3" OR GREATER<br />
DETAIL AT CANOPY RAFTER CONN.<br />
SHT. NO.<br />
DATE<br />
SEE "CROSS SECTION"<br />
FOR BOLT SIZE AND<br />
QUANTITY<br />
WHEN COL. DEPTH IS 1'-3" OR GREATER<br />
FA15
SEE DETAIL MA030701<br />
FOR OUTSIDE CLOSURE<br />
INSTALLATION<br />
STITCH FASTENERS<br />
(2 PER FOOT)<br />
HIGH SIDEWALL<br />
TRIM (SF9)<br />
(STITCH FASTENERS<br />
3'-0" 0.C.)<br />
EAVE FLASHING<br />
(SF90, SF91)<br />
TF10 OR TF11<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
SELF-DRILLERS<br />
(1'-0" O.C.)<br />
EAVE<br />
STRUT<br />
1 " DIA.<br />
2<br />
A325 BOLTS<br />
RIGID FRAME<br />
COLUMN<br />
HIGH SIDE EAVE LINE FLUSH<br />
CANOPY RAFTER AT OPEN WALL<br />
(RIBBED ROOF)<br />
1 " A325<br />
2<br />
BOLTS<br />
EAVE STRUT<br />
1 "<br />
2<br />
DIA.<br />
A325 BOLTS<br />
TF10 OR TF11<br />
STITCH FASTENERS<br />
(1'-0" O.C.)<br />
SOFFIT PANELS<br />
TF72<br />
1 "<br />
2<br />
DIA.<br />
A325 BOLTS<br />
1 " DIA.<br />
2<br />
A325<br />
BOLTS<br />
REV.<br />
Dec. 09 01<br />
DETAIL AT CANOPY RAFTER CONN.<br />
WHEN COL. DEPTH IS 1'-3" OR GREATER<br />
DETAIL AT CANOPY RAFTER CONN.<br />
WHEN COL. DEPTH IS 1'-3" OR GREATER<br />
SHT. NO.<br />
DATE<br />
SELF-DRILLERS (SEE<br />
MA030401/MA030501)<br />
SEE "CROSS SECTION"<br />
FOR BOLT SIZE AND<br />
QUANTITY<br />
CANOPY RAFTER<br />
FA16<br />
CANOPY<br />
RAFTER
NOTE: ERECTOR<br />
TO FIELD "PITCH"<br />
ROOF SHEETS AT<br />
EAVE GUTTER<br />
EAVE GUTTER<br />
(EG2-4)<br />
EAVE FLASHING<br />
(SF70, SF71)<br />
TF10 OR TF11<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
CANOPY<br />
RAFTER<br />
BELOW EAVE LINE<br />
FLUSH CANOPY RAFTER AT SHEETED WALL<br />
(RIBBED ROOF)<br />
SELF-DRILLERS (SEE<br />
MA030401/MA030501)<br />
EAVE CLOSURE REQUIRED<br />
WITH SEALED EAVE OR<br />
CANOPY WITH SOFFIT<br />
PURLIN<br />
CL200<br />
1 " BOLTS<br />
2<br />
TF72<br />
SOFFIT PANELS<br />
CL200<br />
TF10 OR<br />
TF11<br />
SHT. NO.<br />
DATE<br />
FA17<br />
REV.<br />
MAR. 06 00<br />
BASE FLASHING (BF76)<br />
(SEE DETAIL MA030701)<br />
SELF-DRILLERS<br />
(2 PER FOOT)<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
GIRT<br />
ANGLE<br />
SELF-DRILLERS<br />
(2 PER FOOT)<br />
STITCH FASTENERS<br />
(1'-0" O.C.)<br />
COLUMN<br />
3 "<br />
4<br />
DIA.<br />
A325 BOLTS
NOTE: ERECTOR TO FIELD<br />
"PITCH" ROOF SHEETS AT<br />
EAVE GUTTER<br />
SELF-DRILLERS (SEE<br />
MA030401/MA030501)<br />
EAVE CLOSURE REQUIRED<br />
WITH SEALED EAVE<br />
EAVE<br />
GUTTER<br />
(EG2-4)<br />
EAVE FLASHING<br />
(SF70)<br />
STITCH FASTENERS<br />
(3'-0" O.C.)<br />
PURLIN<br />
CANOPY<br />
RAFTER<br />
BELOW EAVE LINE<br />
FLUSH CANOPY RAFTER AT OPEN WALL<br />
(RIBBED ROOF)<br />
1 " BOLTS<br />
2<br />
CL200<br />
BASE FLASHING (BF76)<br />
(SEE DETAIL MA030701)<br />
CL200<br />
3 " A325<br />
4<br />
BOLTS<br />
SELF-DRILLERS<br />
(2 PER FOOT)<br />
CANOPY<br />
RAFTER<br />
SHT. NO.<br />
DATE<br />
FA18<br />
REV.<br />
MAR. 06 00<br />
GIRT<br />
COLUMN
EAVE STRUT<br />
CHANNEL<br />
1 " DIA.<br />
2<br />
A325 BOLTS<br />
RIGID FRAME<br />
COLUMN<br />
PURLIN SUPPORT CHANNEL DETAIL<br />
SHT. NO.<br />
DATE<br />
PURLIN<br />
FA35<br />
REV.<br />
MAR. 06 00<br />
ST FASTENERS