Tube Bundle Connectivity - Emtelle Scandinavia A/S
Tube Bundle Connectivity - Emtelle Scandinavia A/S
Tube Bundle Connectivity - Emtelle Scandinavia A/S
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Air Blown Fibre FttX Customers Fibre Products <strong>Tube</strong> <strong>Bundle</strong> Sub-Duct Accessories Installation Equipment Tools Training <strong>Emtelle</strong> Offi ces Terms & Conditions<br />
16<br />
Environmental Performance*<br />
Test Test Method Test Parameters<br />
Temperature Cycle IEC 60794-1-2-F1<br />
(3 cycles)<br />
Mechanical Performance*<br />
Microcable FU product codes<br />
Pan Weights and Dimensions (ext. height x diameter)<br />
<strong>Emtelle</strong> can also offer non-standard<br />
lengths. These may be subject to longer<br />
lead-times than our standard product<br />
range. Please call your local <strong>Emtelle</strong><br />
representative to check for availability. Small: diameter 540mm, height 200mm, Medium: diameter 540mm, height 300mm,<br />
Large: diameter 540mm. height 400mm<br />
I N N O V A T I O N A N D F L E X I B I L I T Y<br />
FIBRE PRODUCTS S<br />
Fibre Count single mode ITU-T multi mode<br />
G.652d G.657A1 G.655 62.5/125<br />
OM1<br />
50/125<br />
OM2<br />
50/125<br />
OM3<br />
50/125<br />
OM4<br />
2 9032 9506 - 9021 7653 9058 9180<br />
4 7590 9507 - 7578 7577 6669 9181<br />
6 90024 - - - - - -<br />
8 7589 9509 - 7580 7583 6668 9182<br />
12 7575 9510 9179 7582 7581 7714 9013<br />
Generic Specifi cation MHT1201 MHT2185 MHT1202 MHT1203<br />
Order Example 2 fi bre G652d = Product Code 9032 and specify standard length required<br />
Standard<br />
Length<br />
2 fi bre 4 fi bre 6 fi bre 8 fi bre 12 fi bre<br />
12,000m 16.5 kg<br />
Large<br />
– – –<br />
6,000m 10 kg<br />
Medium<br />
4,000m 6.5 kg<br />
Small<br />
2,000m 4.5 kg<br />
Small<br />
+20°C, -40°C, +60°C<br />
≤0.1dB change during and after test<br />
Water Soak IEC 60794-5 18°C / 22°C<br />
≤0.1dB change during and after test<br />
Damp Heat Cycle IEC 60068-2-38<br />
(10 cycles)<br />
Test Test Method Test Parameters<br />
Tensile Performance (EN 187000 A1/ 501<br />
IEC60 794-12-E1)<br />
Change @ 1550nm<br />
Flexing IEC 60794-1-2-E11A<br />
Change @ 1550nm<br />
Crush I IEC 60794-1-2-E3<br />
Change @ 1550nm<br />
Crush II IEC 60794-1-2-E3<br />
Change @ 1550nm<br />
*Singlemode fi bre. For multimode fi bre, see datasheet MHT1203<br />
25°C, 65°C, 25°C, 65°C, 25°C , -10°C, 25°C<br />
≤0.1dB change during and after test<br />
Load is 1x w (in kg) (eg 12fu is 2.2kg)<br />
10 min<br />
0.05dB change after test<br />
Diam 40mm x 3 turns<br />
5 cycles at 20°C<br />
≤0.05dB change after test<br />
100 mm plate, 100N,<br />
1 min, 2 tests at different places<br />
≤0.05dB change after test<br />
100 mm plate, 500N,<br />
1 min, 2 tests at different places<br />
≤0.05dB change after test<br />
14.0 kg<br />
Large<br />
10.2 kg<br />
Medium<br />
5.7 kg<br />
Small<br />
15.0 kg<br />
Large<br />
11.0 kg<br />
Medium<br />
6.0 kg<br />
Small<br />
18 kg<br />
Large<br />
13.0 kg<br />
Medium<br />
7.0 kg<br />
Small<br />
At <strong>Emtelle</strong> we strive to improve our products every day and therefore strongly suggest that all new orders and specifications be confirmed by your <strong>Emtelle</strong> representative. The current specifications may be different<br />
from those listed in our latest catalogues, which are limited by publication date. For the latest specifications please visit our website at www.emtelle.com or contact your <strong>Emtelle</strong> representative.