Figure 4 - Wiring, <strong>MK2000</strong><br />
L1<br />
L2<br />
12VDC CM<br />
A<br />
B<br />
RI1<br />
K1/NC<br />
K1/COM<br />
K1/NO<br />
SAFE<br />
HAZARD<br />
RI2<br />
GND2<br />
LIMGND<br />
TEST<br />
1S1<br />
Z1/M+<br />
1S2<br />
Z2/M-<br />
K2/COM<br />
K2/NC<br />
K2/NO<br />
CP-LIM2010<br />
Connector Plate<br />
Figure 5 - Wiring, <strong>MK2000</strong>C<br />
L1<br />
L2<br />
12VDC CM<br />
A<br />
B<br />
RI1<br />
K1/NC<br />
K1/COM<br />
K1/NO<br />
SAFE<br />
HAZARD<br />
RI2<br />
GND2<br />
LIMGND<br />
TEST<br />
1S1<br />
Z1/M+<br />
1S2<br />
Z2/M-<br />
K2/COM<br />
K2/NC<br />
K2/NO<br />
CP-LIM2010<br />
Connector Plate<br />
L1 to<br />
load center<br />
Figure 6 - Wiring, <strong>MK2000</strong>P<br />
L1<br />
L2<br />
12VDC CM<br />
A<br />
B<br />
RI1<br />
K1/NC<br />
K1/COM<br />
K1/NO<br />
SAFE<br />
HAZARD<br />
RI2<br />
GND2<br />
LIMGND<br />
TEST<br />
1S1<br />
Z1/M+<br />
1S2<br />
Z2/M-<br />
K2/COM<br />
K2/NC<br />
K2/NO<br />
CP-LIM2010<br />
Connector Plate<br />
T M<br />
STW3 / STW4<br />
SAFE<br />
HAZARD<br />
To<br />
load center<br />
SAFE<br />
HAZARD<br />
To<br />
load center<br />
SAFE<br />
HAZARD<br />
L1 from<br />
transformer<br />
secondary<br />
To<br />
load center<br />
<strong>Bender</strong> Inc. • USA: 800.356.4266 / 610.383.9200 / medical@bender.org • Canada: 800.243.2438 / 905.602.9990 / info@bender-ca.com • www.bender.org<br />
MUTE<br />
TEST<br />
RESET<br />
MENU<br />
To panel<br />
ground bus<br />
ESC<br />
LIM2010<br />
MUTE<br />
TEST<br />
RESET<br />
MENU<br />
To panel<br />
ground bus<br />
ESC<br />
LIM2010<br />
MUTE<br />
TEST<br />
RESET<br />
MENU<br />
To panel<br />
ground bus<br />
ESC<br />
LIM2010<br />
<strong>MK2000</strong><br />
<strong>MK2000</strong>C<br />
<strong>MK2000</strong>P<br />
Figure 7 - Wiring, <strong>MK2000</strong>CP<br />
L1<br />
L2<br />
12VDC CM<br />
A<br />
B<br />
RI1<br />
K1/NC<br />
K1/COM<br />
K1/NO<br />
SAFE<br />
HAZARD<br />
RI2<br />
GND2<br />
LIMGND<br />
TEST<br />
1S1<br />
Z1/M+<br />
1S2<br />
Z2/M-<br />
K2/COM<br />
K2/NC<br />
K2/NO<br />
CP-LIM2010<br />
Connector Plate<br />
L1 to<br />
load center<br />
<strong>MK2000</strong>(C)(P) <strong>Series</strong><br />
Installation Bulletin / Reference Guide<br />
STW3 / STW4<br />
SAFE<br />
HAZARD<br />
To<br />
load center<br />
L1 from<br />
transformer<br />
secondary<br />
Technical Data<br />
Operating voltage 12V DC or 12V AC<br />
Max. current 50 mA<br />
(<strong>MK2000</strong>CBM 100 mA)<br />
Operation class<br />
Ambient temperature<br />
continuous operation<br />
when operating +32º F to +122º F<br />
0º C to +50º<br />
when stored -13º F to +158º F<br />
-25º C to +70º C<br />
Connection screw terminal block<br />
Conductor size AWG 30…12<br />
Tightening torque 5…7 lb-in.<br />
Mounting<br />
Weight<br />
by screws<br />
<strong>MK2000</strong>-G1 / <strong>MK2000</strong>P-G1 / <strong>MK2000</strong>C-G1 / <strong>MK2000</strong>CP-G1 0.25 lb<br />
<strong>MK2000</strong>-G2 / <strong>MK2000</strong>CBM 0.32 lb<br />
MUTE<br />
TEST<br />
RESET<br />
MENU<br />
To panel<br />
ground bus<br />
ESC<br />
LIM2010<br />
<strong>MK2000</strong>CP<br />
Figure 8 - Wiring, <strong>MK2000</strong>CBM<br />
Refer to <strong>MK2000</strong>CBM installation bulletin, document NAE2028450 for instructions and wiring<br />
diagram for installing an <strong>MK2000</strong>CBM remote indicator.<br />
Document NAE2028520 • 11.2012 • © <strong>Bender</strong> Inc. • Page 1/1 • Side 2/2