02.04.2013 Views

Orthopedic

Orthopedic

Orthopedic

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Section of anatomical bone plates for operation on distal femur<br />

Tel. +49-74 62- 94 45-0 · Fax +49-74 62 - 94 45-20<br />

info@reda-instrumente.de · www.reda-instrumente.de<br />

Distal Femur Plate 4.5 mm<br />

Distal Femur Platte 4.5 mm<br />

Plaque pour femur distal 4.5 mm<br />

Indication: Anatomical distal femur<br />

bone plates are designed to be used<br />

for reducing fractures of the distal<br />

femur with or without involvement of<br />

the joint. The anatomical bone plate<br />

features show the following important<br />

factors to osteosynthesis as;<br />

permit a stable fixation of the small<br />

proximal and distal fragments. They<br />

consider the various physiological<br />

stability factors of distal spongiosa<br />

and meta-to diaphyseal fractures.<br />

They are curved and twisted to<br />

conform to the nature shape of the<br />

proximal and distal bones areas.<br />

They simplify reduction in case of<br />

extended fractures as their anterior<br />

surface is contoured to minimize<br />

tissue irritation.<br />

Plate details: The shape of distal<br />

femur bone plate is particularly well<br />

suited for accommodating the<br />

ventral convex curve of the normal<br />

femur, as well as its specific twisting.<br />

The plate thickness is reduced<br />

towards the distal direction in accordance<br />

with the different stability<br />

Ref. No<br />

Stainless Steel<br />

ROT-245080-05 R<br />

ROT-245122-07 R<br />

ROT-245158-09 R<br />

ROT-245194-11 R<br />

ROT-245230-13 R<br />

ROT-245080-05 L<br />

ROT-245122-07 L<br />

ROT-245158-09 L<br />

ROT-245194-11 L<br />

ROT-245230-13 L<br />

relationship of diaphysis to metaphysis.<br />

The pre-formed shape of the<br />

plate requires that a separate plate to<br />

be used for righ and left femur.<br />

Plate thickness: 5.0 mm<br />

Plate width: 16.0 mm<br />

Head width: 25.5 mm<br />

Hole spacing: 18.0 mm<br />

Screws to be used: Head of plate<br />

accept 6.5 mm cancellous screws.<br />

Plate shaft accepts 4.5 mm cortical<br />

screws. The screw holes into distal<br />

and are placed so as to allow<br />

cancellous screw to be placed in<br />

different directions. Two small holes<br />

at the very end of the plate are for<br />

temporary fixation with kirschner<br />

wires. An oval hole in the proximal<br />

part of the plate permit fixation with<br />

an excentrically or medially placed<br />

cortical screw while allowing enough<br />

room for application of a compression<br />

device.<br />

Material: Certified Stainless Steel<br />

according to ASTM F.138 - ISO<br />

5832/1.<br />

In Titanium on request.<br />

Style<br />

Right<br />

Right<br />

Right<br />

Right<br />

Right<br />

Left<br />

Left<br />

Left<br />

Left<br />

Left<br />

Holes<br />

5<br />

7<br />

9<br />

11<br />

13<br />

5<br />

7<br />

9<br />

11<br />

13<br />

Length<br />

mm<br />

80<br />

122<br />

158<br />

194<br />

230<br />

80<br />

122<br />

158<br />

194<br />

230<br />

2/47