SOLENOID/PILOT – ELECTRICAL OPERATOR SPECIFICATIONS<br />

Solenoid/Pilot actuated Series V & T valves are available with a variety of different solenoids for both nonhazardous and hazardous<br />

locations. Basic details of actuators are listed below. For additional data consult factory.<br />

NONHAZARDOUS LOCATION SOLENOIDS (Inline or upright style)<br />

Suffix Protection Area Classification Certification Ingress<br />

Identification Classification and (Gas Grouping) (Conformance) Protection<br />

HAZARDOUS LOCATION SOLENOIDS (upright style only)<br />

Suffix Protection Area Classification Certification Ingress<br />

Identification Classification and (Gas Grouping) (Conformance) Protection<br />

V-3.7<br />

None General Purpose Indoor & Outdoor CSA NEMA 1,2,3<br />

or<br />

-U<br />

-HC General Purpose Indoor & Outdoor CSA NEMA 4;<br />

-HCC IP65<br />

-XX Hazardous Locations Class I, Division 2 (A & B) UL NEMA 7 & 9<br />

Class I, Division 1 (C & D) CSA<br />

Class II, Division 1 (E,F,G)<br />

-3567 Hazardous Locations Class I, Division 2 (A & B) UL NEMA 7 & 9<br />

Class I, Division 1 (C & D) CSA<br />

Class II, Division 1 (E,F,G)<br />

-XN (d) Flameproof Zones 1 & 2 ATEX IP66<br />

(IIB+H 2 ) Category 2G<br />

T4<br />

-LB-XN (d) Flameproof Zones 1 & 2 ATEX IP66<br />

(IIB+H 2 ) Category 2G<br />

T6<br />

-XDAS (d) Flameproof Zones 1 & 2 ATEX IP66 & IP67<br />

or (IIC) Category 2G<br />

-XDAT<br />

-XMAA (m) Encapsulation Zones 1 & 2 ATEX IP66 & IP67<br />

or (e) Increased Safety (II) Category 2G<br />

-XMAE<br />

or<br />

-XMAF<br />

or<br />

-XMAG<br />

XMFA (m) Encapsulation Zones 1 & 2 ATEX IP66 & IP67<br />

or (e) Increased Safety (II) Category 2G<br />

-XMFE<br />

or<br />

-XMFF<br />

or<br />

-XMFG<br />

-HC-XISC Hazardous Locations Class I, Groups (A,B,C,D) Factory Mutual NEMA 4<br />

-HCC-XISC Class II, Groups (E,F,G) CSA<br />

Class III, Division 1<br />

-HC-XISX6 (ia) Intrinsic Safe Zones 0, 1 and 2, ATEX IP65<br />

-HCC-XISX6 (IIC) Category 1G<br />

T6<br />

-XIFA (ib) Intrinsic Safe Zones 1 & 2 ATEX IP66 & IP67<br />

or (IIB) Category 1G<br />

-XIFE<br />

or<br />

-XIFF<br />

* See page V-3.5 for more detailed voltage/coil data.<br />