SOLENOID/PILOT — COIL SPECIFICATIONS<br />
<strong>SERIES</strong><br />
V-3.5<br />
COIL COVER — Standard provides 1/2" NPT female conduit connection.<br />
Use Suffix –243 for grommeted housing with wire leads.<br />
Use Suffix –HC or –HCC for DIN style coil connector.<br />
COILS — Standard coil lead lengths are at least 24" (60cm). Consult factory for availability of longer lead lengths.<br />
CONTINUOUS DUTY COIL VOLTAGES* AC DC<br />
V or T ORDINARY - Standard,<br />
or Suffix -243,<br />
HAZARDOUS Suffix -P,<br />
Suffix -XX<br />
Suffix-HC,<br />
ORDINARY DIN or -HCC<br />
HAZARDOUS<br />
[(d) Flameproof]<br />
SOLENOID OPERATOR<br />
(Service & Type)<br />
Low Watt<br />
Suffix-3567<br />
or<br />
-LB-XN<br />
Suffix-XDAS or-XDAT<br />
24/60 A024<br />
120/60 A120<br />
240/60 A240<br />
480/60 A480<br />
24/50 E024<br />
110/50 F120<br />
230/50 E230<br />
240/50 E240<br />
120/60 A120<br />
240/60 A240<br />
110/50 E110<br />
220/50 E220<br />
12/60 A012<br />
24/60 A024<br />
48/60 A048<br />
120/60 A120<br />
240/60 A240<br />
24/60 A024<br />
120/60 A120<br />
240/60 A240<br />
24/50 E024<br />
127/50 E127<br />
230/50 E230<br />
Suffix-XN 24/60 A024<br />
120/60 A120<br />
240/60 A240<br />
24/50 E024<br />
110/50 E110<br />
220/50 E220<br />
240/50 E240<br />
— —<br />
8<br />
1.30<br />
0.26<br />
0.13<br />
0.07<br />
1.05<br />
0.23<br />
0.11<br />
0.11<br />
0.20<br />
0.13<br />
0.20<br />
0.13<br />
0.63<br />
0.13<br />
0.06<br />
0.61<br />
0.13<br />
0.07<br />
0.06<br />
0.82<br />
0.16<br />
0.08<br />
0.04<br />
0.67<br />
0.15<br />
0.07<br />
0.07<br />
0.16<br />
0.08<br />
0.16<br />
0.08<br />
0.30<br />
0.15<br />
0.07<br />
0.03<br />
0.02<br />
0.38<br />
0.08<br />
0.04<br />
0.37<br />
0.08<br />
0.04<br />
0.04<br />
6<br />
146<br />
593<br />
2365<br />
9<br />
193<br />
700<br />
876<br />
205<br />
845<br />
205<br />
845<br />
11<br />
43<br />
175<br />
1085<br />
5050<br />
19<br />
475<br />
2000<br />
25<br />
475<br />
2030<br />
2714<br />
6 D006<br />
12 D012<br />
24 D024<br />
48 D048<br />
125 D125<br />
12 D012<br />
24 D024<br />
48 D048<br />
12 D012<br />
24 D024<br />
28 D028<br />
48 D048<br />
110 D110<br />
125 D125<br />
6 D006<br />
12 D012<br />
24 D024<br />
47 D047<br />
125 D125<br />
HAZARDOUS<br />
Hazardous Locations Suffix -HC-XISC, -HCC-XISC — — — — — 24 D024<br />
[(ia) Intrinsic Safe] Suffix -HC-XISX6, -HCC-XISX6 — — — — — 24 D024<br />
[(ib) Intrinsic Safe] Suffix -XIFA, -XIFE, -XIFF — — — — — 24 D024<br />
HAZARDOUS<br />
[(m) Encapsulation] Suffix -XMFA, -XMFE<br />
[(e) Increased Safety] -XMFF, -XMFG<br />
Suffix -XMAA, -XMAE,<br />
-XMAF, -XMAG<br />
Coil<br />
Voltage Code #<br />
Inrush<br />
Amp<br />
0.58<br />
0.20<br />
0.14<br />
0.06<br />
0.03<br />
* Coils for voltages other than those listed above, may be available.<br />
Class H (Suffix –HT) coils are available for both ordinary and hazardous service.<br />
Contact factory for availability and delivery information.<br />
Holding<br />
Amp Ohm<br />
Coil<br />
Voltage Code #<br />
6 D006<br />
12 D012<br />
24 D024<br />
48 D048<br />
120 D120<br />
— — — 24 D024<br />
Amp-Inrush<br />
& Holding Ohm<br />
1.54<br />
0.78<br />
0.38<br />
0.19<br />
0.08<br />
0.86<br />
0.44<br />
0.21<br />
0.32<br />
0.16<br />
0.08<br />
0.04<br />
0.02<br />
1.30<br />
0.63<br />
0.32<br />
0.16<br />
0.06<br />
4<br />
16<br />
63<br />
249<br />
1675<br />
14<br />
55<br />
225<br />
19<br />
75<br />
312<br />
1337<br />
7815<br />
5<br />
19<br />
75<br />
295<br />
2030<br />
24 D024 — —