V-30<br />
3<br />
WAY <strong>VALVES</strong> 3/2 and 3/3<br />
Three-Way <strong>Valves</strong> may be either normally open or normally closed to the<br />
inlet in the unactuated position. Three-Way <strong>Valves</strong> are usually used to<br />
control single acting cylinders or the pilots of other valves or devices.<br />
Two additional types of Three-Way <strong>Valves</strong> are available. Diverter: a common<br />
inlet that directs flow to either one of two outlets. Selector: two separate<br />
inlets that are alternately connected to a common outlet.<br />
NOMINAL PRESSURE RANGE ACTUATION<br />
(Consult pressure rating chart on page V-3.3<br />
for specific pressure rating of each valve.)<br />
Series “V”: partial vacuum to 200 psi (14 bar) pneumatic<br />
Series “T”: 0-500 psi (35 bar) hydraulic<br />
BODY TYPES:<br />
26<br />
MANUAL, MECHANICAL, PILOT<br />
or SOLENOID-PILOT<br />
All Series “V” & “T” Three-Way <strong>Valves</strong> are available in the two body types<br />
described below. Actuators used with either body type are completely<br />
interchangeable.<br />
SIDE-PORTED SUB-PLATE MOUNTING<br />
The side-ported body provides threaded The Sub-plate mounting valve is shown mounted<br />
ports in the body of the valve. on an individual sub-plate. See page V-35.1 for<br />
details on the sub-plate.<br />
PORT SIZES: 1/8, 1/4, 3/8, 1/2, 3/4, and 1 NPT PORT SIZES: 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4 NPT and G<br />
1/8, 1/4, 3/8, and 1/2 G