Bottle In Positioning<br />

<strong>Application</strong> <strong>Case</strong><br />

- 2 -<br />

Measuring<br />

Industrial Automation BU, <strong>Delta</strong> <strong>Electronics</strong>, Inc.<br />

Filling Bottle Out<br />

Weighing<br />

The weighing process in the filling adopts <strong>Delta</strong>’s DVP02LC-SL load cell left-side extension module to weigh the<br />

filled bottle. The 12-bit analog output in DVP-SX2 PLC is responsible for the bottle in and out process and VFD series<br />

AC motor drive in charge of transporting empty bottles on the conveyer belt. The entire filling process can also be<br />

realized by pneumatic cylinder, pushing the empty bottle to a certain position for filling and to the next stop for the<br />

next process. The operation of the pneumatic cylinder relies on the I/O control from the PLC. DVP-SX2 series PLC is<br />

extendable to max. 494 points, which is capable enough of handling the I/O control on most of the liquid fillers.<br />