Transceivermodule 1 TRX433-10A / TRX868-10A (Vers. 1.0E ...
Transceivermodule 1 TRX433-10A / TRX868-10A (Vers. 1.0E ...
Transceivermodule 1 TRX433-10A / TRX868-10A (Vers. 1.0E ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Transceivermodule</strong> 10 <strong>TRX433</strong>-<strong>10A</strong> / <strong>TRX868</strong>-<strong>10A</strong> (<strong>Vers</strong>. <strong>1.0E</strong>)<br />
rf-mode: Setup for radio transmission:<br />
1 = 19.2 kbit radio datarate, 100kHz channel grid (Maximum data speed)<br />
2 = 4.8 kbit radio datarate, 25kHz channel grid (Standard setup)<br />
3 = 1.2 kbit radio datarate, 12.5kHz channel grid (Maximum sensitivity)<br />
handshake: Flow control: (for reliable communication flow control should always be activated)<br />
1 = no flow control<br />
2 = Hardware (RTS/CTS)<br />
3 = Software (XON/XOFF)<br />
The configuration mode can be terminated with the ESC-Key or it will terminate automatically after 1 Minute<br />
of no data activity.<br />
If you want a parameter not to change, hit the Enter-Key without any number input.<br />
The configuration is saved into the EEPROM of the <strong>Transceivermodule</strong> and will remain there permanently.<br />
Notice:<br />
• The configuration must be done always with 19.2kbaud, even if you configured another baudrate<br />
• The signal RTS/CFG (Pin 9) must be tied to a logic low level by a pulldown resistor during normal<br />
operation, in order not to activate the configuration mode during powerup.<br />
• Always input the numbers with three figures, including the leading zeros<br />
• With the standard 868MHz Transceiver, only use rf-mode = 3, if the temperature range in use is<br />
between 5°C and 40°C.