────────────────────<br />

- PROFIB SCROLL 3 - Password: SERVICE<br />

Write buffer dim<br />

48 words<br />

ENTER<br />

────────────────────<br />

Default: 48<br />

Min 5<br />

Max 48<br />

────────────────────<br />

In the TEST SCROLL it is possible to check the actual status of the communication.<br />

────────────────────<br />

- TEST SCROLL 8 - Password: SERVICE<br />

Test communication B<br />

19.2 kb Wait Prm<br />

────────────────────<br />

In the third line the baud rate and status are dynamically displayed. The status can be:<br />

WAIT PRM it is waiting for the PARAMETER message<br />

WAIT CFG it is waiting for the CONFIGURATION message<br />

DATA EXC it is in the DATA EXCHANGE phase , configuration and parametrization have been<br />

completed successfully.<br />

The baud rate is automatically detected by the instrument, if the displayed value changes continuously it<br />

means that there are problems on the line or the CPU is OFF.<br />