Three-phase A.C. <strong>motors</strong><br />

Construction types<br />

The construction types of <strong>electric</strong> <strong>motors</strong> and their symbols comply with the standards EN 60034-7. Our <strong>motors</strong> are available in basic<br />

construction types IM B3, IM B5 and IM B14.<br />

The table shows the symbols and the installation options of the standard mo<strong>de</strong>ls we manufacture. The type IM B3 <strong>motors</strong> can also be<br />

operated in the mounting positions IM B6, IM B7 and IM B8. As well as the flange sizes allocated in line with the standard, a number<br />

of other flange sizes can also be supplied (see page 1/11). On all construction types with the shaft end at the bottom the version "with<br />

safety cover" must be selected in or<strong>de</strong>r to prevent foreign bodies from falling in.<br />

IP protection classes<br />

The protection classes of circulating <strong>electric</strong> machines are <strong>de</strong>noted by an abbreviation in line with EN 60034-5. It consists of the<br />

letter IP (international protection) and two numbers.<br />

1st number ( 0 to 6 ): Protection level for contact and foreign body protection.<br />

2nd number ( 0 to 8 ): Protection level for water protection.<br />

The <strong>motors</strong> are constructed with protection class IP 55. Motors can be supplied with a higher protection class on request.<br />

Protection from solids and liquids: IP protection class<br />

Protection class Protection from contact and the penetration of solid substances (first number)<br />

IP 55 / IP 56 Full protection from contact with live and moving internal parts.<br />

Protection from penetration from dust.<br />

The penetration of dust is not completely prevented but cannot take on such a scale as to have a<br />

negative effect on operation of the machine.<br />

IP 65* Complete protection from contact with live or moving internal parts.<br />

Penetration of dust is fully prevented.<br />

Protection class Protection from penetration of water (second number)<br />

IP 55 / IP65* The motor is <strong>protected</strong> from jets of water from all directions.<br />

IP56 Machine <strong>protected</strong> from heavy seas.<br />

Water from heavy seas or a strong jet of water must not penetrate into the housing in damaging<br />

quantities.<br />

* All vertically installed <strong>motors</strong> with an open shaft end at the top must be <strong>protected</strong> in such a way that no foreign objects can fall into<br />

the fan cover from above. However, this protection is not necessary if the machine is fitted with such a protective mechanism itself.<br />

Motors installed in the open must be <strong>protected</strong> from direct sunlight.<br />